Only Slide
PQA 8000H Rack Mount

Permanent Precision. Built for the Grid.

The Premium Device for Professional Monitoring

With the new PQA 8000H-RM, NEO Messtechnik brings the full measurement capability of the PQA 8000H into a 19″ rackmount form factor — designed for permanent installation in substations, battery energy storage systems, and grid-connected infrastructure. The instrument retains all hardware and software capabilities of its portable variant, while adding a higher-performance processor and up to four integrated IPCS 10A Zeroflux sensors.

Without display or battery, the PQA 8000H-RM is purpose-built for headless, continuous operation and remote access.

Alt Text
  • Accuracy: 0.05% / 0.01% (PMU)
  • Sampling Rate: 1 MS/s, Resolution: 18 bit
  • Supraharmonics: up to 500 kHz
  • Voltage Inputs: 4x, up to 800 V / 1600 V
  • Current Inputs: up to 8x (Rogowski, Clamp AC/DC, Zeroflux)
  • Dynamic Range: 0.5 mA to 150 kA (15 ranges)
  • Isolation: 6 kV (CH–GND)
  • Safety: CAT III 1000V / CAT IV 600V
  • Interfaces: LAN / WLAN / LTE / Bluetooth / GPS / CAN / RS485 / Digital IO
  • Power Quality Class: A++ — exceeds IEC61000-4-30 Ed.3 and Ed.4
  • PMU: IEC/IEEE 60255-118-1, TVE ≤ 0.01%, angle error ≤ 0.003°

Hardware Highlights

Permanent Installation

19″ rack mount form factor for substations, control cabinets, and infrastructure environments. No display, no battery — built for continuous unattended operation.

Higher-Performance Processor

More computing power than the portable PQA 8000, enabling faster real-time processing and simultaneous high-resolution data streams.

Up to 4x Integrated Zeroflux Sensors

IPCS 10A Zeroflux current sensors included — highest accuracy AC/DC current measurement, directly powered by the instrument.

GPS Time Synchronisation

Highly precise UTC-referenced time stamping — fundamental to PMU synchrophasor measurements and wide-area monitoring applications.

Up to 1 TB SSD Storage

Continuous raw data recording at full 1 MS/s sampling rate. Local storage combined with remote access via LAN, WLAN, or LTE.

Remote Access

No on-site presence required for configuration, monitoring, or data retrieval.

Software Highlights

All measurement, analysis, and reporting functions are available remotely:

  • Synchrophasor & RoCoF measurement (PMU, IEC/IEEE 60255-118-1)
  • Power quality monitoring, harmonics, interharmonics, supraharmonics up to 500 kHz
  • Transient recording and disturbance analysis
  • Continuous raw data recording at full sampling rate
  • Wide Area Monitoring (WAMS) via SmartGRID EDGE PDC
  • Report generation: EN50160, IEEE519, IEC61000-2-4 and others
  • Export: CSV, XLS, PDF, Comtrade, PQDiff

Technical Excellence That Delivers Results

The PQA 8000H-RM shares its voltage level coverage, current sensor compatibility, supraharmonic measurement, safety specifications, complying standards, and software functions with the portable NEO PQA 8000H.

[See full measurement specifications on the PQA 8000H page]

Built In Phasor Measurement Unit

The PQA 8000H-RM includes full PMU functionality compliant with IEC/IEEE 60255-118-1. It measures synchrophasors, frequency, and Rate of Change of Frequency (RoCoF) — all referenced to UTC via GPS.

  • TVE (Total Vector Error): ≤ 0.01% — 100× more accurate than the 1% standard requirement
  • Angle accuracy: ≤ 0.003°
  • Reporting rates: up to 200 fps (Class M and P simultaneously)
  • TCP and UDP streaming to PDC
  • Compatible with SmartGRID EDGE WAMS software

More key facts and figures

according to IEC 61000-4-30 Ed.3 and IEC 62586

Harmonics, Interharmonics and THD:
Class A
Higher Frequencies and Supraharmonics:
2 – 9 kHz (200 Hz band)
2 – 500 kHz (2 kHz band)
Symmetrical Components & Unbalance:
Class A ((Pos-, Neg- and Zero Sequence))
Flicker (PST, PLT, Pinst) and RVC:
Class A

.

Voltage Events:
Class A (dip, swell, interruption – time, extrema, length)
Frequency:
10 sec, AVE, MIN, MAX
Voltage, Current:
RMS, AVE, MIN, MAX, ½ Period-values, 200ms, 10s, 10min
Time Synchronisation:
Class A

Alt Text

Power Calculation:
P, Q, S, PF, cos phi, D, DH, QH

Frequency:
10 sec, AVE, MIN, MAX

Voltage, Current:
RMS, AVE, MIN, MAX, ½ Period-values, 200ms, 10s, 10min

Power Calculation:
P, Q, S, PF, cos phi, D, DH, QH

Energy:
Total, positive, negative (P, Q, P+, P-, Q+, Q-)

Efficiency:
DC / AC, U-I Curve for PV

Wiring:
DC, 1-Phase, 2-Phase, 3-Phase Star and Delta

Alt Text

MIN, MAX, RMS, AVE:
U, I, P, Q, S, f, PF, phi, THD, Harmonics, Interharm., Unbalance, etc.
ENVELOPE / WINDOW:
U, I
DELTA:
dU, dI, df, dP, etc.

DERIVATE (RATE OF CHANGE):
dU/dt, df/dt etc. … per ms, number of periods or half-period
VOLTAGE SIGNALLING:
Threshold
EN50160:
Trigger on any EN50160 parameter (Max, Quantil)

Alt Text

1/2 PERIOD TRIGGER:
U, I, P, Q, S, f, PF, phi, THD, Harmonics, Interharm., Unbalance, etc.

SYMMETRICAL COMPONENTS:
Positive-, Negative-, Zerosequence

Phasor Measurement Unit (PMU)
according to IEEE C37.118: Total Vector Error 0.01% (typ.), Angle Error 0.003°(typ)

RATE OF CHANGE OF FREQUENCY (ROCOF)

POWER QUALITY, HARMONICS, FLICKER:
IEC61000-4-30 Ed. 3 Class A / IEC61000-4-7 / IEC61000-4-15 /  IEC62586-2 Ed. 2 / IEC62586-1
PUBLIC GRID, RAILWAY AND INDUSTRY
EN50160 / EN50163 / IEC61000-2-2 / IEC61000-2-4 (Class 1; 2; 3) / IEEE519  / IEEE 1159 / IEC61000-2-12 / NRS048
WIND POWER, RENEWABLES AND GRID CODES
IEC61400-21 / IEC61400-12 / FGW-TR3 / VDE N-4105 / VDE N-4100 / VDE N-4110 / D-A-CH-CZ / BDEW / ROCOF / IEEE C37.118-2005 (PMU)
MOTORS, TRANSFORMERS AND ELECTRICAL EQUIPMENT
IEC60034 / IEC 60076-1 / IEC61000-3-2 / IEC61000-3-3 / IEC61000-3-11 / IEC61000-3-12

PQA8000 RM: Standard instrument configuration with 4 current inputs

PQA8000-P RM: Instrument with 6x current inputs and 2x Analogue Inputs

PQA8000-M RM: Instrument with 8x current inputs

OPTION-DC 110V: Option DC power supply from 48V to 110V DC (instead of 24 – 48V DC)

Screw terminals are also available as an option for the voltage inputs and for the power supply

The PQA 8000H-RM is deployed wherever continuous, high-precision power quality monitoring is required over extended periods — without the need for on-site operation.

Substations & Grid Connection Points Permanent monitoring of voltage quality, harmonics, and grid events at transmission and distribution level.

Battery Energy Storage Systems (BESS) High-accuracy measurement for FCAS compliance, asset verification, and grid support documentation.

Renewable Energy Integration Monitoring of PV, wind, and hybrid installations — including DC measurements and grid code compliance assessment.

Wide Area Monitoring (WAMS) Multi-site synchrophasor data via PDC integration — real-time grid observability across large geographic areas.

Industrial & Railway Power quality assessment in industrial grids, railway supply systems, and high-distortion environments.

Research & Grid Model Validation High-resolution waveform data for grid simulation validation, model calibration, and post-event analysis.

NEO Applications

reveal what conventional measurement cannot detect