NEO PQA 8000 - Mobile Power Quality Analyzer
As the year progresses NEO Messtechnik continues to evolve and demonstrates once again the ability to forge its long-standing expertise of the Power Quality market into yet another impressive PQ Analyzer that enables engineers to stay ahead of the curve.
With the new PQA 8000, you can measure supraharmonic currents and voltages up to 150 kHz / 500 kHz as needed. Our unique measuring device allows continuous recording of raw data at full sampling rate or use an extension box to determine the grid impedance up to 150 kHz or 450 kHz. You can access the device at any time using TeamViewer© or Anydesk©, making it suitable for installation in control cabinets. Should any issues or uncertainties arise, we offer remote support to assist you.
HARDWARE
Power Quality
Class A ++
High Sampling Rate
124kS/s or 1MS/s
High Accuracy
0.05%
High Resolution
18bit / 24bit
High Dynamic
0.5mA to 150kA
High Safety
CAT IV 600V
High Performance
WINDOWS PC with Multi-Touch and battery pack
High Connectivity
additional input signals, Interfaces, AC&DC power, etc.
SOFTWARE
Supraharmonics up to 500kHz
Harmonics, Inter- Supraharmonics, THD
WORLD LEADING
Visualisations
Recorder, Waveform, FFT, Vector, Table, etc.
Transient Recording
Waveform & Disturbance Trigger
Disturbance
triggering & storing of raw data, 1/2 period data or 10 period data
Continuous Storing of
raw data in full sampling rate, 1/2 period data or 10 period data
System Dynamics
Resonances, Phase Angle Jumps, etc.
Phasor Measurement Unit (PMU)
and RoCoF
Report
EN50160, IEEE519, IEC61000-2-4, etc.

HARDWARE
State of the Art
-
Smart Touch
11 inch full-HD Smart Touch display
-
Mobile Operation
up to 4 hours of operation.
-
Sensor Supply
for current clamps and sensors (uni- and bipolar)
-
Weight and Dimensions
4 kg, 298 x 225 x 95mm


-
GPS
for highly-precise time synchronization
-
Large SSD
up to 1 TB data storage
-
Interfaces
USB 3.0, TCP/IP, LAN, Wifi, Bluetooth, RS232, Modbus, 104, DIO, and CAN.
Highest Quality
Multi System
Sync.
Multi-Touch Display
Sunlight-readable


Batterypack 4h
Mixed System
Connectivity
Remote
Charger integrated
MEASUREMENT IN ALL VOLTAGE LEVELS
up to 1600 V

- Voltage up to 1600 V direkt
up to 500 kHz - Accuracy: 0.05%
- Sampling Rate: 1 MS/s
- SNR: >90dB
- Gain Drift: max. 20ppm/K
- Resolution: 18bit
- Current Measurement via Rogowski up to 500 kHz
10-36 kV

- Voltage Divider (T-piece)
up to 150 kHz
- Details can be read in the datasheet of the sensors
- Current Measurement via Rogowski up to 500 kHz
110 – 380 kV

- Voltage measurement via
capactive voltage coupling, see:
- Current Measurement via
Senseleq Zero flux transducer transducer
CURRENT MEASUREMENT

- up to 8 inputs for current clamps or Rogowski coils
- Accuracy: 0.05%
- Bandwidth: 500kHz
- Sampling rate: 1 MS/s
- Input for Rogowski coil with integrated integrator
- Integrator measuring ranges: 30A, 300A, 3kA, 30kA, 120 kA
- Current clamp measuring ranges from 10mV to 10V (min. 10 measuring ranges)
All sensors directly powered by instrument!
(Bipolar (±15V), Unipolar (+9V)
Multiple measurement ranges:
2mV, 20mV, 200mV, 500mV, 1V, 2V, 5V, 10V
Selecting the Right Rogowski Coil:
The NEO Power Quality Blog
While modern Rogowski coil systems can measure a wide range of currents regardless of coil size, the relationship between coil diameter and conductor diameter significantly impacts measurement accuracy.
Understanding this relationship is essential for achieving reliable, high-quality measurements.

EXAMPLE USE CASE OF PQA 8000

HIGHEST PRECISION FOR HIGH-FREQUENCY

POWER QUALITY MEASUREMENTS
- Class A according to IEC61000-4-30 Ed.3
- Supraharmonic voltages up to 150kHz or 500kHz
- Supraharmonic currents up to 150kHz or 500kHz
- Evaluation according to IEC61000-2-2:2020, EN50160, IEC61000-3-2, etc.
- PMU functionality (TVE: max. 0.01%, angle 0.003°)
- Raw data recording with trigger release up to 60 seconds
- 1/2 period recording for fault triggering up to 1h
- Continuous raw data recording in full sampling rate also possible
- Power measurement with 0.05% accuracy
- Correction factors for voltage and current sensors for amplitude and frequency
- Evaluation software without licensing
COMPLYING STANDARDS
POWER QUALITY, HARMONICS, FLICKER:
IEC61000-4-30 Ed. 3 Class A / IEC61000-4-7 / IEC61000-4-15 / IEC62586-2 Ed. 2 / IEC62586-1
WIND POWER, RENEWABLES AND GRID CODES:
IEC61400-21 / IEC61400-12 / FGW-TR3 / VDE-N 4105 / VDE-N 4100 / VDE-N 4110 / D-A-CH-CZ / BDEW / ROCOF / IEEE C37.118-2005 (PMU)
PUBLIC GRID, RAILWAY AND INDUSTRY:
EN50160 / EN50163 / IEC61000-2-2 / IEC61000-2-4 (Class 1;2;3) / IEEE1159 / IEEE519 / IEC61000-2-12 / NRS048
MOTORS, TRANSFORMERS AND ELECTRICAL EQUIPMENT:
IEC60364 / IEC6076-1 / IEC61000-3-2 / IEC61000-3-3 / IEC61000-3-11 / IEC61000-3-12
POWER QUALITY MEASUREMENTS REGARDING D-A-CH-CZ Ed. 3 LIMITS
- New: Compliance assessment based on the latest grid connection requirements for Germany, Austria, Czech Republic, and Slovakia
- Precise analysis of grid disturbances with the PQA 8000 and GIA (Grid Impedance Analyzer)
- Compatible with NEO Report Tool: Exporting measured data to D-A-CH-CZ Analysis tool
- Easy to use: Simply upload CSV files – automatic compliance check
- Result documentation: PDF export for seamless processing


Flyer of PQA8000:
(Englisch)
Flyer des PQA8000:
(German)

SELECT YOUR COLOUR
Choose between many different colours and align the instrument style to your companies CI.
Standard colours: Green, Yellow, Black, Red, Blue
The NEO Sensor Integration
Highest Precision

HIGH BANDWIDTH & HIGH ACCURACY
Conventional PQ Analyzers, even if they are Class A certified, are not sufficient for modern measurement applications. We use the best available components to ensure the highest safety category and also the highest accuracy. NEO instruments offer high bandwidth (up to 1 MHz) and correct the frequency dependent behavior of current & voltage sensors as well as integrated electronics to achieve the best possible measurement results
SENSOR INTEGRATION
All current sensors offered by NEO Messtechnik are industry proven for different applications. We use and improve on the best available sensors in the market.
FREQUENCY DEPENDENT CALIBRATION
The NEO sensor integration calibrates each sensor over a wide frequency bandwidth and corrects frequency dependent phase shift and amplitude damping. This allows for high precision from DC to high-frequency measurements.
MEASUREMENT RANGE DEPENDENT CALIBRATION
In addition, the sensors will calibrated for each measurement range using multiple points. The calibration will typically cover points from 1% to 100% of the nominal measurement range. This will improve the accuracy and precision, especially at low current (e.g., 1% of nominal measurement range).


LEADING IN SAFETY
Overvoltages from power lines down to factories can be higher than normal operating voltages. To avoid any kind of electrical accident, NEO Messtechnik emphasizes the importance of a safe instrument design. For example, the high-voltage inputs of the PQA 8000 instrument (CAT IV 600V) are isolated up to 6kVp while maintaining high precision (0.05%) and high sampling (up to 1MS/s). This is world-leading technology.
Truly Intuitive Software
Clearly structured. Explicit Menus.
1. SETUP
The instrument has a clear structure that
shows schematics with explanations.


2. MEASURE
During measurements the user can define widgets such as Scopes, Vector Scopes, Harmonic FFTs, Tables, and Recorders.
3. ANALYSE
Sophisticated functions include PQ Data, Transients, Disturbances, and Alarms.

4. REPORT
The instrument can automatically generate reports and professional documentation. The user can create reports that include all relevant information (location, comments, company logo, etc) directly on-site or during post processing. PDF reports that are saved on the instrument are always available and can be shared directly via email.



5. EXPORT
Data can be exported into CSV, XLS, PDF, Comtrade, and PQDiff.
6. OTHER PROGRAMS
The instrument uses Microsoft Windows© as the operating system. Programs such as Microsoft Excel, Word or Matlab can be added as well as Email messaging services.
World's best Power Quality Analyser

Datasheet
Instrument Options
PQA8000
4x Voltage Input 1600V DC
4x Current Input (Rogowski, Clamp)
CAN / RS485
PQA8000-P
4x Voltage Input 1600V DC
6x Current Input (Rogowski, Clamp)
2x Analog Input (± 10V)
CAN / RS485 / DIO
PQA8000-M
4x Voltage Input 1600V DC
8x Current Input (Rogowski, Clamp)
CAN / RS485 / DIO

Key Features

according to IEC 61000-4-30 Ed.3 and IEC 62586
Harmonics, Interharmonics and THD:
Class A
Higher Frequencies and Supraharmonics:
2 – 9 kHz (200 Hz band)
2 – 500 kHz (2 kHz band)
Symmetrical Components & Unbalance:
Class A ((Pos-, Neg- and Zero Sequence))
Flicker (PST, PLT, Pinst) and RVC:
Class A
.
Voltage Events:
Class A (dip, swell, interruption – time, extrema, length)
Frequency:
10 sec, AVE, MIN, MAX
Voltage, Current:
RMS, AVE, MIN, MAX, ½ Period-values, 200ms, 10s, 10min
Time Synchronisation:
Class A

Power Calculation:
P, Q, S, PF, cos phi, D, DH, QH
Frequency:
10 sec, AVE, MIN, MAX
Voltage, Current:
RMS, AVE, MIN, MAX, ½ Period-values, 200ms, 10s, 10min
Power Calculation:
P, Q, S, PF, cos phi, D, DH, QH
Energy:
Total, positive, negative (P, Q, P+, P-, Q+, Q-)
Efficiency:
DC / AC, U-I Curve for PV
Wiring:
DC, 1-Phase, 2-Phase, 3-Phase Star and Delta

MIN, MAX, RMS, AVE:
U, I, P, Q, S, f, PF, phi, THD, Harmonics, Interharm., Unbalance, etc.
ENVELOPE / WINDOW:
U, I
DELTA:
dU, dI, df, dP, etc.
DERIVATE (RATE OF CHANGE):
dU/dt, df/dt etc. … per ms, number of periods or half-period
VOLTAGE SIGNALLING:
Threshold
EN50160:
Trigger on any EN50160 parameter (Max, Quantil)

1/2 PERIOD TRIGGER:
U, I, P, Q, S, f, PF, phi, THD, Harmonics, Interharm., Unbalance, etc.
SYMMETRICAL COMPONENTS:
Positive-, Negative-, Zerosequence
Phasor Measurement Unit (PMU)
according to IEEE C37.118: Total Vector Error 0.01% (typ.), Angle Error 0.003°(typ)
RATE OF CHANGE OF FREQUENCY (ROCOF)
POWER QUALITY, HARMONICS, FLICKER:
IEC61000-4-30 Ed. 3 Class A / IEC61000-4-7 / IEC61000-4-15 / IEC62586-2 Ed. 2 / IEC62586-1
PUBLIC GRID, RAILWAY AND INDUSTRY
EN50160 / EN50163 / IEC61000-2-2 / IEC61000-2-4 (Class 1; 2; 3) / IEEE519 / IEEE 1159 / IEC61000-2-12 / NRS048
WIND POWER, RENEWABLES AND GRID CODES
IEC61400-21 / IEC61400-12 / FGW-TR3 / VDE N-4105 / VDE N-4100 / VDE N-4110 / D-A-CH-CZ / BDEW / ROCOF / IEEE C37.118-2005 (PMU)
MOTORS, TRANSFORMERS AND ELECTRICAL EQUIPMENT
IEC60034 / IEC 60076-1 / IEC61000-3-2 / IEC61000-3-3 / IEC61000-3-11 / IEC61000-3-12
Learn more about ..
How Not To – Out-dated Measurement Approach
Analysing the effects of Supraharmonics asks for Power Quality Analyzer that cover a frequency range up to 500 kHz. Classical PQ Analyzers present problems because of their limited bandwidth. Typically they can measure up to the 50th Harmonics (2.5kHz), but cannot detect higher emissions of voltage and currents. By design, they are not able to be used in the troubleshooting process at all.
How To – Troubleshooting with the PQA 8000
On the applications page, we outline the complexity and shortcomings of traditional measurement approaches we often see out in the field. Fortunately, all these problems do not concern engineers with the appropriate measurement equipment. Our customers appreciate the PQA8000H in troubleshooting Supraharmonic emissions, where its strengths really come into play ..