{"id":8717,"date":"2024-07-15T12:21:08","date_gmt":"2024-07-15T10:21:08","guid":{"rendered":"https:\/\/www.neo-messtechnik.com\/?p=8717"},"modified":"2025-10-07T10:38:45","modified_gmt":"2025-10-07T08:38:45","slug":"unbalance-of-single-phase-charging-stations","status":"publish","type":"post","link":"https:\/\/www.neo-messtechnik.com\/en\/unbalance-of-single-phase-charging-stations","title":{"rendered":"Unbalance of single-phase charging stations"},"content":{"rendered":"\n<p class=\"has-text-align-left has-black-color has-text-color has-link-color wp-elements-3199edccd3bd29551ce8e8a227d6a59b\">If an electric vehicle is charged at home some chargers operate in single phase mode.<br>Some charging stations allow single-phase charging above the single-phase unbalanced load current limit.<br>According to <a href=\"https:\/\/www.e-control.at\/documents\/1785851\/1811582\/TOR_Verteilernetzanschluss_-_Niederspannung_V1.2.pdf\/e1f3db67-1dbf-6329-9fe6-1ce63c9b4bd4?t=1720509810680\">TOR <\/a>the single phase current is limited with 16A in Austria and 20A (VDE-standard) in Germany.<\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-c5b4a0fa7dac774e680f4426a61b8a82\">Different voltage levels on the three phases and a shifted neutral point, as well as high neutral currents can occur. Unbalance will increase heating of electrical equipment and shorten their life-time.<\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-de252a86746b11bef7ea1fac6131e0d4\">Especially single-phase chargers can have a huge impact, while three-phase chargers can also have an effect as they are not perfectly balanced or sometimes only use two-phases for specific charging states. Sometimes one phase is generally not activated for the whole charging process, other charging strategies use the three phases at different times which again leads to temporary unbalanced systems.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<label for=\"ez-toc-cssicon-toggle-item-69facc2e15feb\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #000000;color:#000000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #000000;color:#000000\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-69facc2e15feb\" checked aria-label=\"Toggle\" \/><nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-1'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.neo-messtechnik.com\/en\/unbalance-of-single-phase-charging-stations\/#Experiment_%E2%80%93_Charging_with_23Arms\" >Experiment &#8211; Charging with 23Arms<\/a><ul class='ez-toc-list-level-2' ><li class='ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.neo-messtechnik.com\/en\/unbalance-of-single-phase-charging-stations\/#Where_can_I_get_more_information\" >Where can I get more information?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n<h1 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Experiment_%E2%80%93_Charging_with_23Arms\"><\/span>Experiment &#8211; Charging with 23Arms<span class=\"ez-toc-section-end\"><\/span><\/h1>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1013\" height=\"548\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-15-113101.png\" alt=\"\" class=\"wp-image-8720\" style=\"width:668px;height:auto\" srcset=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-15-113101.png 1013w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-15-113101-300x162.png 300w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/Screenshot-2024-07-15-113101-18x10.png 18w\" sizes=\"auto, (max-width: 1013px) 100vw, 1013px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-left has-black-color has-text-color has-link-color wp-elements-77690c19070b73ce0d0876056b48ffe4\">Here an electric vehicle is charged with 23A in single phase mode. <\/p>\n\n\n\n<p class=\"has-text-align-left has-black-color has-text-color has-link-color wp-elements-1bb53e7250775f7e6bb93581ffed2ea0\">During the experiment the Power Quality Analyzer <a href=\"https:\/\/www.neo-messtechnik.com\/en\/pqa8000\">PQA8000H<\/a> detected an undervoltage at the office in <a href=\"https:\/\/maps.app.goo.gl\/EPRV5gKsysHFL8V3A\">Z\u00f6bern, Austria<\/a> which is seen in the following diagram:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1271\" height=\"703\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/Unymmetrical-EV-charging.png\" alt=\"\" class=\"wp-image-8833\" style=\"width:698px;height:auto\" srcset=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/Unymmetrical-EV-charging.png 1271w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/Unymmetrical-EV-charging-300x166.png 300w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/Unymmetrical-EV-charging-1024x566.png 1024w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/Unymmetrical-EV-charging-1085x600.png 1085w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/Unymmetrical-EV-charging-18x10.png 18w\" sizes=\"auto, (max-width: 1271px) 100vw, 1271px\" \/><\/figure>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-ff4f9e231298860864875a3bbe58bafa\">Due to the unbalanced current the voltage of the loaded phase is dropping (blue). In the low-voltage grid, a voltage drop of up to 10% is permitted. This means that the lower limit is reached at 207V.<\/p>\n\n\n\n<p class=\"has-black-color has-text-color has-link-color wp-elements-da45e16d8efafd538a2e2fad000b1e59\">Using long extension cables or too low diameter of electrical installation amplifies this effect. The charger won\u2019t start charging or will abort after a short time.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Where_can_I_get_more_information\"><\/span>Where can I get more information?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<div class=\"wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items8717_a81170-9a kt-svg-icon-list-columns-1 alignnone kt-list-icon-aligntop\"><ul class=\"kt-svg-icon-list\">\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-8717_69611d-d3 kt-svg-icon-list-style-default\"><span data-name=\"fe_checkCircle\" data-stroke=\"2\" data-class=\"kt-svg-icon-list-single\" class=\"kadence-dynamic-icon\"><\/span><span class=\"kt-svg-icon-list-text\">Simply click on the link and <strong><a href=\"https:\/\/www.neo-messtechnik.com\/en\/pqa8000\">visit the product site<\/a><\/strong><\/span><\/li>\n\n\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-8717_d79890-72 kt-svg-icon-list-style-default\"><span data-name=\"fe_checkCircle\" data-stroke=\"2\" data-class=\"kt-svg-icon-list-single\" class=\"kadence-dynamic-icon\"><\/span><span class=\"kt-svg-icon-list-text\">Request an <strong>online-product demo<\/strong><\/span><\/li>\n\n\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-8717_ecbca0-63 kt-svg-icon-list-style-default\"><span data-name=\"fe_checkCircle\" data-stroke=\"2\" data-class=\"kt-svg-icon-list-single\" class=\"kadence-dynamic-icon\"><\/span><span class=\"kt-svg-icon-list-text\">We are <a href=\"https:\/\/www.neo-messtechnik.com\/en\/about-us\" target=\"_blank\" rel=\"noreferrer noopener\">a simple phone call<\/a> or E-Mail away. We look forward to hear from you:<\/span><\/li>\n\n\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-8717_de49b7-ba kt-svg-icon-list-style-default\"><span data-name=\"fe_checkCircle\" data-stroke=\"2\" data-class=\"kt-svg-icon-list-single\" class=\"kadence-dynamic-icon\"><\/span><span class=\"kt-svg-icon-list-text\">Austria:<br><strong>+43 2642 20301<\/strong><\/span><\/li>\n<\/ul><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:sales@neo-messtechnik.com\">Austria<\/a><\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:info@schotec.ch\">Switzerland<\/a><\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:neo@neomez.com\">South Korea<\/a><\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:sales@dewe-tech.cn\">China<\/a><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p>Your <a href=\"https:\/\/www.linkedin.com\/company\/neo-messtechnik\/\">NEO Messtechnik experts<\/a><\/p>\n\n\n\n<ul class=\"wp-block-social-links is-layout-flex wp-block-social-links-is-layout-flex\"><li class=\"wp-social-link wp-social-link-linkedin  wp-block-social-link\"><a href=\"https:\/\/linkedin.com\/company\/neo-messtechnik\" class=\"wp-block-social-link-anchor\"><svg width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\" focusable=\"false\"><path d=\"M19.7,3H4.3C3.582,3,3,3.582,3,4.3v15.4C3,20.418,3.582,21,4.3,21h15.4c0.718,0,1.3-0.582,1.3-1.3V4.3 C21,3.582,20.418,3,19.7,3z M8.339,18.338H5.667v-8.59h2.672V18.338z M7.004,8.574c-0.857,0-1.549-0.694-1.549-1.548 c0-0.855,0.691-1.548,1.549-1.548c0.854,0,1.547,0.694,1.547,1.548C8.551,7.881,7.858,8.574,7.004,8.574z M18.339,18.338h-2.669 v-4.177c0-0.996-0.017-2.278-1.387-2.278c-1.389,0-1.601,1.086-1.601,2.206v4.249h-2.667v-8.59h2.559v1.174h0.037 c0.356-0.675,1.227-1.387,2.526-1.387c2.703,0,3.203,1.779,3.203,4.092V18.338z\"><\/path><\/svg><span class=\"wp-block-social-link-label screen-reader-text\">LinkedIn<\/span><\/a><\/li>\n\n<li class=\"wp-social-link wp-social-link-youtube  wp-block-social-link\"><a href=\"https:\/\/www.youtube.com\/channel\/UC0SItHb-UNY0WNUhQtqhB7w\" class=\"wp-block-social-link-anchor\"><svg width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\" focusable=\"false\"><path d=\"M21.8,8.001c0,0-0.195-1.378-0.795-1.985c-0.76-0.797-1.613-0.801-2.004-0.847c-2.799-0.202-6.997-0.202-6.997-0.202 h-0.009c0,0-4.198,0-6.997,0.202C4.608,5.216,3.756,5.22,2.995,6.016C2.395,6.623,2.2,8.001,2.2,8.001S2,9.62,2,11.238v1.517 c0,1.618,0.2,3.237,0.2,3.237s0.195,1.378,0.795,1.985c0.761,0.797,1.76,0.771,2.205,0.855c1.6,0.153,6.8,0.201,6.8,0.201 s4.203-0.006,7.001-0.209c0.391-0.047,1.243-0.051,2.004-0.847c0.6-0.607,0.795-1.985,0.795-1.985s0.2-1.618,0.2-3.237v-1.517 C22,9.62,21.8,8.001,21.8,8.001z M9.935,14.594l-0.001-5.62l5.404,2.82L9.935,14.594z\"><\/path><\/svg><span class=\"wp-block-social-link-label screen-reader-text\">YouTube<\/span><\/a><\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>If an electric vehicle is charged at home some chargers operate in single phase mode.Some charging stations allow single-phase charging above the single-phase unbalanced load current limit.According to TOR the single phase current is limited with 16A in Austria and 20A (VDE-standard) in Germany. Different voltage levels on the three phases and a shifted neutral [&hellip;]<\/p>\n","protected":false},"author":2140,"featured_media":8724,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[50,1],"tags":[104,105,103],"class_list":["post-8717","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-and-trends","category-pq-essentials","tag-electric-vehicle","tag-single-phase-charging","tag-unbalance"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Unbalance of single-phase charging stations - NEO Messtechnik<\/title>\n<meta name=\"description\" content=\"The 2nd edition of the blog post &quot;Types of faults in photovoltaic modules&quot; is coming late but still. This time it&#039;s all about hot spots.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.neo-messtechnik.com\/en\/unbalance-of-single-phase-charging-stations\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Unbalance of single-phase charging stations - NEO Messtechnik\" \/>\n<meta property=\"og:description\" content=\"The 2nd edition of the blog post &quot;Types of faults in photovoltaic modules&quot; is coming late but still. This time it&#039;s all about hot spots.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.neo-messtechnik.com\/en\/unbalance-of-single-phase-charging-stations\/\" \/>\n<meta property=\"og:site_name\" content=\"NEO Messtechnik\" \/>\n<meta property=\"article:published_time\" content=\"2024-07-15T10:21:08+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-07T08:38:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/image001-2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"621\" \/>\n\t<meta property=\"og:image:height\" content=\"199\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Harald\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Harald\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations\"},\"author\":{\"name\":\"Harald\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/person\\\/be9f619759151273e7b4a73859efb2b8\"},\"headline\":\"Unbalance of single-phase charging stations\",\"datePublished\":\"2024-07-15T10:21:08+00:00\",\"dateModified\":\"2025-10-07T08:38:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations\"},\"wordCount\":294,\"publisher\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/image001-2.png\",\"keywords\":[\"electric vehicle\",\"single phase charging\",\"Unbalance\"],\"articleSection\":[\"News &amp; Trends\",\"PQ Essentials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations\",\"name\":\"Unbalance of single-phase charging stations - NEO Messtechnik\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/image001-2.png\",\"datePublished\":\"2024-07-15T10:21:08+00:00\",\"dateModified\":\"2025-10-07T08:38:45+00:00\",\"description\":\"The 2nd edition of the blog post \\\"Types of faults in photovoltaic modules\\\" is coming late but still. This time it's all about hot spots.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations#primaryimage\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/image001-2.png\",\"contentUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/image001-2.png\",\"width\":621,\"height\":199},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/unbalance-of-single-phase-charging-stations#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"News &amp; Trends\",\"item\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/de\\\/kategorie\\\/news-and-trends\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Unbalance of single-phase charging stations\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"name\":\"NEO Messtechnik\",\"description\":\"Power Quality with perfection\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\",\"name\":\"NEO Messtechnik GmbH\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"contentUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"width\":466,\"height\":264,\"caption\":\"NEO Messtechnik GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/linkedin.com\\\/company\\\/neo-messtechnik\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/person\\\/be9f619759151273e7b4a73859efb2b8\",\"name\":\"Harald\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/edc15dace761507d29d3ccb1afcff9fbb15db44ad259065ea6aade23e618996f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/edc15dace761507d29d3ccb1afcff9fbb15db44ad259065ea6aade23e618996f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/edc15dace761507d29d3ccb1afcff9fbb15db44ad259065ea6aade23e618996f?s=96&d=mm&r=g\",\"caption\":\"Harald\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Unbalance of single-phase charging stations - NEO Messtechnik","description":"The 2nd edition of the blog post \"Types of faults in photovoltaic modules\" is coming late but still. This time it's all about hot spots.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.neo-messtechnik.com\/en\/unbalance-of-single-phase-charging-stations\/","og_locale":"en_US","og_type":"article","og_title":"Unbalance of single-phase charging stations - NEO Messtechnik","og_description":"The 2nd edition of the blog post \"Types of faults in photovoltaic modules\" is coming late but still. This time it's all about hot spots.","og_url":"https:\/\/www.neo-messtechnik.com\/en\/unbalance-of-single-phase-charging-stations\/","og_site_name":"NEO Messtechnik","article_published_time":"2024-07-15T10:21:08+00:00","article_modified_time":"2025-10-07T08:38:45+00:00","og_image":[{"width":621,"height":199,"url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/image001-2.png","type":"image\/png"}],"author":"Harald","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Harald","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations#article","isPartOf":{"@id":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations"},"author":{"name":"Harald","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/person\/be9f619759151273e7b4a73859efb2b8"},"headline":"Unbalance of single-phase charging stations","datePublished":"2024-07-15T10:21:08+00:00","dateModified":"2025-10-07T08:38:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations"},"wordCount":294,"publisher":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations#primaryimage"},"thumbnailUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/image001-2.png","keywords":["electric vehicle","single phase charging","Unbalance"],"articleSection":["News &amp; Trends","PQ Essentials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations","url":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations","name":"Unbalance of single-phase charging stations - NEO Messtechnik","isPartOf":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations#primaryimage"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations#primaryimage"},"thumbnailUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/image001-2.png","datePublished":"2024-07-15T10:21:08+00:00","dateModified":"2025-10-07T08:38:45+00:00","description":"The 2nd edition of the blog post \"Types of faults in photovoltaic modules\" is coming late but still. This time it's all about hot spots.","breadcrumb":{"@id":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations#primaryimage","url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/image001-2.png","contentUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/07\/image001-2.png","width":621,"height":199},{"@type":"BreadcrumbList","@id":"https:\/\/www.neo-messtechnik.com\/unbalance-of-single-phase-charging-stations#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.neo-messtechnik.com\/"},{"@type":"ListItem","position":2,"name":"News &amp; Trends","item":"https:\/\/www.neo-messtechnik.com\/de\/kategorie\/news-and-trends"},{"@type":"ListItem","position":3,"name":"Unbalance of single-phase charging stations"}]},{"@type":"WebSite","@id":"https:\/\/www.neo-messtechnik.com\/en\/#website","url":"https:\/\/www.neo-messtechnik.com\/en\/","name":"NEO Messtechnik","description":"Power Quality with perfection","publisher":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.neo-messtechnik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization","name":"NEO Messtechnik GmbH","url":"https:\/\/www.neo-messtechnik.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","contentUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","width":466,"height":264,"caption":"NEO Messtechnik GmbH"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/linkedin.com\/company\/neo-messtechnik"]},{"@type":"Person","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/person\/be9f619759151273e7b4a73859efb2b8","name":"Harald","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/edc15dace761507d29d3ccb1afcff9fbb15db44ad259065ea6aade23e618996f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/edc15dace761507d29d3ccb1afcff9fbb15db44ad259065ea6aade23e618996f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/edc15dace761507d29d3ccb1afcff9fbb15db44ad259065ea6aade23e618996f?s=96&d=mm&r=g","caption":"Harald"}}]}},"_links":{"self":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/posts\/8717","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/users\/2140"}],"replies":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/comments?post=8717"}],"version-history":[{"count":14,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/posts\/8717\/revisions"}],"predecessor-version":[{"id":9047,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/posts\/8717\/revisions\/9047"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/media\/8724"}],"wp:attachment":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/media?parent=8717"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/categories?post=8717"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/tags?post=8717"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}