{"id":6897,"date":"2021-09-06T07:37:33","date_gmt":"2021-09-06T05:37:33","guid":{"rendered":"https:\/\/www.neo-messtechnik.com\/?p=6897"},"modified":"2025-10-07T10:39:17","modified_gmt":"2025-10-07T08:39:17","slug":"6-most-common-customer-complaints-pq-analyzer","status":"publish","type":"post","link":"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer","title":{"rendered":"We listened to engineers 6 most common complaints about their current PQ analyser"},"content":{"rendered":"\n<p><strong>We wanted to know how experienced measurement engineers truly think and feel about their current power quality analysers. Read more about the 6 most common customer complaints and how our newest addition to our product family, the brand-new NEO PQA 7000, answers all of them.<\/strong><\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_82_2 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<label for=\"ez-toc-cssicon-toggle-item-69d4c4738ec03\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #000000;color:#000000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #000000;color:#000000\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-69d4c4738ec03\" checked aria-label=\"Toggle\" \/><nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/#Conducting_market_research\" >Conducting market research<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/#You_asked_We_listened\" >You asked. We listened.<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/#Knowing_the_power_quality_market_and_available_instruments\" >Knowing the power quality market and available instruments<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/#The_6_most_common_customer_complaints_requests_and_wishes\" >The 6 most common customer complaints, requests and wishes<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/#NEO_PQA_7000\" >NEO PQA 7000<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/#Forging_something_truly_exceptional\" >Forging something truly exceptional ..<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/#_for_your_benefits_%E2%80%93_the_PQA_7000\" >.. for your benefits &#8211; the PQA 7000<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/#PQA_7000_Software_Highlights\" >PQA 7000 Software Highlights<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/#Wrapping_up\" >Wrapping up<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conducting_market_research\"><\/span>Conducting market research<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"You_asked_We_listened\"><\/span>You asked. We listened.<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Over the last years we have carefully listened to customer requests, wish lists and nice-to-haves engineers and partners have shared with us to eventually come up with a new Power Quality Analyser that <strong>answers all the questions asked<\/strong>. After an extensive time of developing, testing and further improving the initial design prototype we would like to take you behind the scenes of what makes our latest PQ Analyser that special.<\/p>\n\n\n\n<figure class=\"wp-block-kadence-image kb-image6897_d9b281-5c\"><img loading=\"lazy\" decoding=\"async\" width=\"3568\" height=\"1942\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4.png\" class=\"kb-img wp-image-8655\" srcset=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4.png 3568w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4-300x163.png 300w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4-1024x557.png 1024w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4-1102x600.png 1102w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4-1536x836.png 1536w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4-2048x1115.png 2048w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4-18x10.png 18w\" sizes=\"auto, (max-width: 3568px) 100vw, 3568px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Knowing_the_power_quality_market_and_available_instruments\"><\/span>Knowing the power quality market and available instruments<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Over the years we have seen many hardware and software suppliers trying hard to serve customers and engineers with measurement equipment. Sometimes with more, other times with less success. Although the requirements have constantly changed throughout the last 20 years, many instrument manufactures seemed to be reluctant to open up to new ideas, hardware or software platforms. While we have seen many new instruments and gimmicks introduced, these changes and adaptions have rarely seem to appreciate and value the long and close partnerships with customers that had been forged over the years.<\/p>\n\n\n\n<p>We are all too aware of this fact because we have seen it from our own experience. And the solution, in our humble opinion, is simple. All it takes is simply to listen. Simply listening to your customer&#8217;s wishes and needs over the years and thereby valuing the engineer&#8217;s insights that work extensively with your instruments. For us at NEO Messtechnik, it also doesn&#8217;t stop there, as the ongoing support and care we give our customers is a key contribution to the overall success of the power quality assessments we are trying to be helpful with. Furthermore, with the overall continual improvement and development of the power quality market as a whole.<\/p>\n\n\n\n<p>So we see it as a big honour and responsibility at the same to align with our customers needs. After taking you through our thought process, it&#8217;s probably obvious to you as well to simply go out there, touch base with engineers and customers who we know for quite some time and ask the right questions. After all, this is what we have done and we are proud to share the findings with you.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"The_6_most_common_customer_complaints_requests_and_wishes\"><\/span>The 6 most common customer complaints, requests and wishes<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Although we are actually pretty comfortable with our current system, <strong>it would be really comfortable<\/strong> to show live data on the screen that we&#8217;d choose and like to see.<\/li>\n\n\n\n<li>Most importantly, we cannot analyse the entire system as we like because <strong>we cannot measure current input<\/strong> signals beyond the 50th harmonic.<\/li>\n\n\n\n<li>Data storage is <strong>holding us back<\/strong>, we don&#8217;t have the option to extend memory.<\/li>\n\n\n\n<li>For the new measurement equipment we need to <strong>access single devices for monitoring and configuration purposes remotely<\/strong>. The PQ Analyzer needs to be able to do that, the concrete remote software (TeamViewer, FastViewer) is not much of a topic.<\/li>\n\n\n\n<li>The accuracy <strong>needs to hold up <\/strong>throughout the whole frequency range.<\/li>\n\n\n\n<li>For us, <strong>data export and merging is near impossible<\/strong>. It <strong>complicates <\/strong>measurement and analyses processes on an ongoing basis <strong>not to being able to synchronize data of multiple devices<\/strong>.<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-wide\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"NEO_PQA_7000\"><\/span>NEO PQA 7000<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Forging_something_truly_exceptional\"><\/span>Forging something truly exceptional ..<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p>Understanding the engineer&#8217;s perspective is key for us to design and develop products that make it easier to carry out measurement and analyses tasks, especially when they need to be done on a regular basis and with similar setup and data evaluation processes. Summing up, all of the aforementioned challenges of devices on the market and ideas from customers lead us to the PQA 7000.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"_for_your_benefits_%E2%80%93_the_PQA_7000\"><\/span>.. for your benefits &#8211; the PQA 7000<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:64% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide3-1024x576.png\" alt=\"Voltage measurement 1600V 20kHz PQA 7000\" class=\"wp-image-7474 size-full\" srcset=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide3-1024x576.png 1024w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide3-300x169.png 300w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide3-1067x600.png 1067w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide3-768x432.png 768w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide3-16x9.png 16w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide3.png 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p class=\"has-large-font-size\">nothing special.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 61%\"><div class=\"wp-block-media-text__content\">\n<p class=\"has-large-font-size\">pretty unique.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p>Measure higher-frequency currents up to 20 kHz. Enjoy being totally flexible in terms of current sensors and connections.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide4-2-1024x576.png\" alt=\"Higher-frequency current measurement up to 20 kHz\" class=\"wp-image-7438 size-full\" srcset=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide4-2-1024x576.png 1024w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide4-2-300x169.png 300w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide4-2-1067x600.png 1067w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide4-2-768x432.png 768w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide4-2-16x9.png 16w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide4-2.png 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\" style=\"grid-template-columns:59% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide5-2-1024x576.png\" alt=\"PC-based PQ Analyzer\" class=\"wp-image-7467 size-full\" srcset=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide5-2-1024x576.png 1024w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide5-2-300x169.png 300w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide5-2-1067x600.png 1067w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide5-2-768x432.png 768w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide5-2-16x9.png 16w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide5-2.png 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>forget these old bricks ..<\/p>\n\n\n\n<p><\/p>\n\n\n\n<p class=\"has-large-font-size\">PC-based Analyser<\/p>\n\n\n\n<p>it&#8217;s not possible to have even more tools integrated. trust us, we tried.<\/p>\n<\/div><\/div>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-wide\"\/>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-flow wp-block-group-is-layout-flow\">\n<h2 class=\"wp-block-heading\" id=\"3aimtowriteastraighttothepointemailincludethebasicinformationinyouremailtoanswereveryquestion\"><span class=\"ez-toc-section\" id=\"PQA_7000_Software_Highlights\"><\/span>PQA 7000 Software Highlights<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image alignwide size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide7-1024x576.png\" alt=\"Netzqualit\u00e4t Software Highlights Neo Messtechnik\" class=\"wp-image-7484\" srcset=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide7-1024x576.png 1024w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide7-300x169.png 300w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide7-1067x600.png 1067w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide7-768x432.png 768w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide7-16x9.png 16w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2021\/04\/Slide7.png 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-wide\"\/>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wrapping_up\"><\/span>Wrapping up<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Lately we have been receiving a lot of questions around the PQA 7000 as it was only prominently featured on various images and posts. As we are wrapping up this article, we hope we answered all of them!<\/p>\n\n\n\n<p>Where can I get more information?<\/p>\n\n\n\n<div class=\"wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items6897_c706d2-9c kt-svg-icon-list-columns-1 alignnone kt-list-icon-aligntop\"><ul class=\"kt-svg-icon-list\">\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-6897_486067-11 kt-svg-icon-list-style-default\"><span data-name=\"fe_checkCircle\" data-stroke=\"2\" data-class=\"kt-svg-icon-list-single\" class=\"kadence-dynamic-icon\"><\/span><span class=\"kt-svg-icon-list-text\">Simply click on the link and <strong><a href=\"https:\/\/www.neo-messtechnik.com\/pqa-7000\">visit the product site<\/a><\/strong><\/span><\/li>\n\n\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-6897_1c410f-29 kt-svg-icon-list-style-default\"><span data-name=\"fe_checkCircle\" data-stroke=\"2\" data-class=\"kt-svg-icon-list-single\" class=\"kadence-dynamic-icon\"><\/span><span class=\"kt-svg-icon-list-text\">Request an <strong>online-product demo<\/strong><\/span><\/li>\n\n\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-6897_e564fc-e9 kt-svg-icon-list-style-default\"><span data-name=\"fe_checkCircle\" data-stroke=\"2\" data-class=\"kt-svg-icon-list-single\" class=\"kadence-dynamic-icon\"><\/span><span class=\"kt-svg-icon-list-text\">We are are <a rel=\"noreferrer noopener\" href=\"https:\/\/www.neo-messtechnik.com\/en\/about-us\" target=\"_blank\">a simple phone call<\/a> or E-Mail away. We look forward to hear from you<\/span><\/li>\n<\/ul><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:sales@neo-messtechnik.com\">Austria<\/a><\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:info@schotec.ch\">Switzerland<\/a><\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:neo@neomez.com\">South Korea<\/a><\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:sales@dewe-tech.cn\">China<\/a><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p>Your <a href=\"https:\/\/www.linkedin.com\/company\/neo-messtechnik\/\">NEO Messtechnik experts<\/a><\/p>\n\n\n\n<ul class=\"wp-block-social-links is-layout-flex wp-block-social-links-is-layout-flex\"><li class=\"wp-social-link wp-social-link-linkedin  wp-block-social-link\"><a href=\"https:\/\/linkedin.com\/company\/neo-messtechnik\" class=\"wp-block-social-link-anchor\"><svg width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\" focusable=\"false\"><path d=\"M19.7,3H4.3C3.582,3,3,3.582,3,4.3v15.4C3,20.418,3.582,21,4.3,21h15.4c0.718,0,1.3-0.582,1.3-1.3V4.3 C21,3.582,20.418,3,19.7,3z M8.339,18.338H5.667v-8.59h2.672V18.338z M7.004,8.574c-0.857,0-1.549-0.694-1.549-1.548 c0-0.855,0.691-1.548,1.549-1.548c0.854,0,1.547,0.694,1.547,1.548C8.551,7.881,7.858,8.574,7.004,8.574z M18.339,18.338h-2.669 v-4.177c0-0.996-0.017-2.278-1.387-2.278c-1.389,0-1.601,1.086-1.601,2.206v4.249h-2.667v-8.59h2.559v1.174h0.037 c0.356-0.675,1.227-1.387,2.526-1.387c2.703,0,3.203,1.779,3.203,4.092V18.338z\"><\/path><\/svg><span class=\"wp-block-social-link-label screen-reader-text\">LinkedIn<\/span><\/a><\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>NEO Messtechnik continues to evolve and proudly presents the latest addition to the Power Quality Analyzer portfolio with the all new PQA 7000.<\/p>\n","protected":false},"author":1,"featured_media":8655,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[50,1],"tags":[],"class_list":["post-6897","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-and-trends","category-pq-essentials"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Engineers most common complaints about their current PQ analyser<\/title>\n<meta name=\"description\" content=\"Read about the 6 most common customer complaints and how the NEO PQA 7000, our newest addition to our product family, answers all of them.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Engineers most common complaints about their current PQ analyser\" \/>\n<meta property=\"og:description\" content=\"Read about the 6 most common customer complaints and how the NEO PQA 7000, our newest addition to our product family, answers all of them.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/\" \/>\n<meta property=\"og:site_name\" content=\"NEO Messtechnik\" \/>\n<meta property=\"article:published_time\" content=\"2021-09-06T05:37:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-07T08:39:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4-1024x557.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"557\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Neo Messtechnik\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Neo Messtechnik\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer\"},\"author\":{\"name\":\"Neo Messtechnik\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/person\\\/27a4c8b6d00a04e30b0dd5b2de1a41b7\"},\"headline\":\"We listened to engineers 6 most common complaints about their current PQ analyser\",\"datePublished\":\"2021-09-06T05:37:33+00:00\",\"dateModified\":\"2025-10-07T08:39:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer\"},\"wordCount\":781,\"publisher\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/pqa7000_black4.png\",\"articleSection\":[\"News &amp; Trends\",\"PQ Essentials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer\",\"name\":\"Engineers most common complaints about their current PQ analyser\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/pqa7000_black4.png\",\"datePublished\":\"2021-09-06T05:37:33+00:00\",\"dateModified\":\"2025-10-07T08:39:17+00:00\",\"description\":\"Read about the 6 most common customer complaints and how the NEO PQA 7000, our newest addition to our product family, answers all of them.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer#primaryimage\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/pqa7000_black4.png\",\"contentUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/pqa7000_black4.png\",\"width\":3568,\"height\":1942},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/6-most-common-customer-complaints-pq-analyzer#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"News &amp; Trends\",\"item\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/de\\\/kategorie\\\/news-and-trends\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"We listened to engineers 6 most common complaints about their current PQ analyser\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"name\":\"NEO Messtechnik\",\"description\":\"Power Quality with perfection\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\",\"name\":\"NEO Messtechnik GmbH\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"contentUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"width\":466,\"height\":264,\"caption\":\"NEO Messtechnik GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/linkedin.com\\\/company\\\/neo-messtechnik\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/person\\\/27a4c8b6d00a04e30b0dd5b2de1a41b7\",\"name\":\"Neo Messtechnik\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8ec8ef73eecd0238954b68f136713d038332f9e74cb15d249d3591ce49252447?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8ec8ef73eecd0238954b68f136713d038332f9e74cb15d249d3591ce49252447?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8ec8ef73eecd0238954b68f136713d038332f9e74cb15d249d3591ce49252447?s=96&d=mm&r=g\",\"caption\":\"Neo Messtechnik\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/bernhard-grasel\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UC0SItHb-UNY0WNUhQtqhB7w\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Engineers most common complaints about their current PQ analyser","description":"Read about the 6 most common customer complaints and how the NEO PQA 7000, our newest addition to our product family, answers all of them.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/","og_locale":"en_US","og_type":"article","og_title":"Engineers most common complaints about their current PQ analyser","og_description":"Read about the 6 most common customer complaints and how the NEO PQA 7000, our newest addition to our product family, answers all of them.","og_url":"https:\/\/www.neo-messtechnik.com\/en\/6-most-common-customer-complaints-pq-analyzer\/","og_site_name":"NEO Messtechnik","article_published_time":"2021-09-06T05:37:33+00:00","article_modified_time":"2025-10-07T08:39:17+00:00","og_image":[{"width":1024,"height":557,"url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4-1024x557.png","type":"image\/png"}],"author":"Neo Messtechnik","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Neo Messtechnik","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer#article","isPartOf":{"@id":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer"},"author":{"name":"Neo Messtechnik","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/person\/27a4c8b6d00a04e30b0dd5b2de1a41b7"},"headline":"We listened to engineers 6 most common complaints about their current PQ analyser","datePublished":"2021-09-06T05:37:33+00:00","dateModified":"2025-10-07T08:39:17+00:00","mainEntityOfPage":{"@id":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer"},"wordCount":781,"publisher":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer#primaryimage"},"thumbnailUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4.png","articleSection":["News &amp; Trends","PQ Essentials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer","url":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer","name":"Engineers most common complaints about their current PQ analyser","isPartOf":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer#primaryimage"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer#primaryimage"},"thumbnailUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4.png","datePublished":"2021-09-06T05:37:33+00:00","dateModified":"2025-10-07T08:39:17+00:00","description":"Read about the 6 most common customer complaints and how the NEO PQA 7000, our newest addition to our product family, answers all of them.","breadcrumb":{"@id":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer#primaryimage","url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4.png","contentUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2024\/05\/pqa7000_black4.png","width":3568,"height":1942},{"@type":"BreadcrumbList","@id":"https:\/\/www.neo-messtechnik.com\/6-most-common-customer-complaints-pq-analyzer#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.neo-messtechnik.com\/"},{"@type":"ListItem","position":2,"name":"News &amp; Trends","item":"https:\/\/www.neo-messtechnik.com\/de\/kategorie\/news-and-trends"},{"@type":"ListItem","position":3,"name":"We listened to engineers 6 most common complaints about their current PQ analyser"}]},{"@type":"WebSite","@id":"https:\/\/www.neo-messtechnik.com\/en\/#website","url":"https:\/\/www.neo-messtechnik.com\/en\/","name":"NEO Messtechnik","description":"Power Quality with perfection","publisher":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.neo-messtechnik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization","name":"NEO Messtechnik GmbH","url":"https:\/\/www.neo-messtechnik.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","contentUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","width":466,"height":264,"caption":"NEO Messtechnik GmbH"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/linkedin.com\/company\/neo-messtechnik"]},{"@type":"Person","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/person\/27a4c8b6d00a04e30b0dd5b2de1a41b7","name":"Neo Messtechnik","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/8ec8ef73eecd0238954b68f136713d038332f9e74cb15d249d3591ce49252447?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8ec8ef73eecd0238954b68f136713d038332f9e74cb15d249d3591ce49252447?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8ec8ef73eecd0238954b68f136713d038332f9e74cb15d249d3591ce49252447?s=96&d=mm&r=g","caption":"Neo Messtechnik"},"sameAs":["https:\/\/www.linkedin.com\/in\/bernhard-grasel\/","https:\/\/www.youtube.com\/channel\/UC0SItHb-UNY0WNUhQtqhB7w"]}]}},"_links":{"self":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/posts\/6897","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/comments?post=6897"}],"version-history":[{"count":50,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/posts\/6897\/revisions"}],"predecessor-version":[{"id":8694,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/posts\/6897\/revisions\/8694"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/media\/8655"}],"wp:attachment":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/media?parent=6897"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/categories?post=6897"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/tags?post=6897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}