{"id":5405,"date":"2020-04-11T18:21:11","date_gmt":"2020-04-11T16:21:11","guid":{"rendered":"https:\/\/www.neo-messtechnik.com\/hestia\/?page_id=5405"},"modified":"2021-02-16T12:24:54","modified_gmt":"2021-02-16T11:24:54","slug":"pqm-100","status":"publish","type":"page","link":"https:\/\/www.neo-messtechnik.com\/en\/pqm-100","title":{"rendered":"PQM 100"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div id=\"fws_6a14f6895c568\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     wpb_animate_when_almost_visible wpb_fadeIn fadeIn \" style=\"background-color: #ffffff; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 38px;color: #222222;line-height: 44px;text-align: left\" >PQM 100<\/h2><\/div><div class=\"codeless_separator\" style=\" height:2px;  margin-top:-15px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:70px;  background:#ffdd00;  left:0; height:100%; position:absolute;\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"wpb_content_element list\" style=\"\"><ul data-icon=\"moon-checkbox\">\n\t\t\t\t<li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>ACCURACY<\/h6><p>0.1%<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>RESOLUTION<\/h6><p>24bit<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>SAMPLING<\/h6><p>16 kS\/s or 32 kS\/s<\/p><\/dd><\/dl><\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"wpb_content_element list\" style=\"\"><ul data-icon=\"moon-checkbox\">\n\t\t\t\t<li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>SAFETY<\/h6><p>CAT IV 300V<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>MODULAR SYSTEM<\/h6><p>up to 64 ch<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>DYNAMIC<\/h6><p>0,5A to 1,5A<\/p><\/dd><\/dl><\/li><\/ul><\/div><\/div><\/div><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/pqm100_highlichts2.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_left\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f6895ff1a\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     \" style=\"background-color: #f9f9f9; padding-bottom: 0px ; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 36px;color: #1c1c1c;text-align: center\" >Hardware<\/h2><\/div><div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 16px;color: #1c1c1c;line-height: 24px;text-align: center;letter-spacing:6px\" >State of the Art<\/h2><\/div><div class=\"codeless_separator\" style=\" height:1px;  margin-top:0px;  margin-bottom:35px; \"><span class=\"separator\" style=\" width:60px;  background:#ffdd00;  left:50%;height:100%; margin-left: -30px;position: absolute;\"><\/span><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f68960886\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section     wpb_animate_when_almost_visible wpb_fadeIn fadeIn \" style=\"\" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/pqm100_highlights-e1586622914755.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_left\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f68961f48\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     \" style=\"background-color: #f6f6f6; padding-top: 30px ; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-3 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\" services_medium style_1 wpb_content_element\"><div class=\"icon_wrapper\" style=\"background:#FFDD00;\"><i class=\"moon-health\" style=\"color:#ffffff;\"><\/i><\/div><h4><a href=\"#\">Hybrid Data Storage<\/a><\/h4><p>Even if connection is lost, all data is stored locally and will be transferred after reconnection.<\/p><\/div>\n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-3 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\" services_medium style_1 wpb_content_element\"><div class=\"icon_wrapper\" style=\"background:#d3d3d3;\"><i class=\"steadysets-icon-graph\" style=\"color:#ffffff;\"><\/i><\/div><h4><a href=\"#\">Data on demand<\/a><\/h4><p>All data can be transferred continuously or just triggered on demand.<\/p><\/div>\n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-3 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\" services_medium style_1 wpb_content_element\"><div class=\"icon_wrapper\" style=\"background:#d3d3d3;\"><i class=\"steadysets-icon-screen\" style=\"color:#ffffff;\"><\/i><\/div><h4><a href=\"#\">Remote Configuration<\/a><\/h4><p>The instrument can be configured remotely or locally. Either option can also be disabled.<\/p><\/div>\n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-3 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\" services_medium style_1 wpb_content_element\"><div class=\"icon_wrapper\" style=\"background:#d3d3d3;\"><i class=\"steadysets-icon-map-marker\" style=\"color:#ffffff;\"><\/i><\/div><h4><a href=\"#\">Remote Location<\/a><\/h4><p>All data can be transferred via Ethernet and via a GSM connection.<\/p><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f68962f69\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     wpb_animate_when_almost_visible wpb_fadeIn fadeIn \" style=\"background-color: #ffffff; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 38px;color: #222222;line-height: 44px;text-align: left\" >MODULAR ARCHITECTURE<\/h2><\/div><div class=\"codeless_separator\" style=\" height:2px;  margin-top:-15px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:70px;  background:#ffdd00;  left:0; height:100%; position:absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>Modular Architecture as its best. The PQM-100 allows the combination of one CPU module and up to 6 selected input modules into one device. The input modules provide input signal isolation, filtering and A\/D conversion. The CPU module is equipped with a FPGA real-time controller for the calculation of all parameters and to provide all interfaces and data storage.<\/p>\n\n\t\t<\/div> \n\t<\/div> <div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/pqm100-all_neo.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_left\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f68964b77\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section     \" style=\"\" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-4 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<h2>Input Modules<\/h2>\n<p><strong>HV4:<\/strong><br \/>\n4 channels voltage input module up to 600V rms<br \/>\n<strong>HV4LV4:<\/strong><br \/>\n4 channels voltage input module up to 600V rms<br \/>\n4 channels current input module via low-voltage signal 1V rms<\/p>\n<p><strong>LV16:<br \/>\n<\/strong>16 channels low voltage input module 1V rms<\/p>\n\n\t\t<\/div> \n\t<\/div> \n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-4 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<h2><\/h2>\n<p><strong>LV8:<br \/>\n<\/strong>8 channels low voltage input module 1V rms<\/p>\n<p><strong>LA5-1:<\/strong><br \/>\n4 channels current input module 1A rms<br \/>\n<strong>LA5-5:<\/strong><br \/>\n4 channels current input module 5A rms<br \/>\n<strong>DIO:<\/strong><br \/>\n8 x Digital Input<br \/>\n4x Digital Output<\/p>\n\n\t\t<\/div> \n\t<\/div> \n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-4 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/pqm100_schraeg_neo.png\" alt=\"Alt Text\" class=\"type_image animated fadeInLeft alignment_left\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f6896796e\" class=\"vc_row wpb_row vc_row-fluid   row-dynamic-el section-style parallax_section mobile_parallax_section    \" style=\"background-repeat: no-repeat; padding-top: 120px ; padding-bottom: 120px ;  background-image: url(https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/PQM-SCADA-scaled.jpg); background-position: 50% 0px; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"bg-overlay\" style=\"background:rgba(34,34,34,0.8 );\"><\/div><div class=\"container animate_onoffset light\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 38px;color: #ffffff;line-height: 44px;text-align: center\" >SOFTWARE<\/h2><\/div><div class=\"codeless_separator\" style=\" height:2px;  margin-top:-15px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:70px;  background:#ffdd00;  left:50%;height:100%; margin-left: -35px;position: absolute;\"><\/span><\/div><div class=\"textbar style_2 wpb_content_element \"><h2>PQM-SCADA is the enterprise management software for Power Quality Analysers.<\/h2><a href=\"https:\/\/www.neo-messtechnik.com\/hestia\/?page_id=4764\" class=\"btn-bt default\"><span>PQM-SCADA<\/span><i class=\"linecon-icon-world\"><\/i><\/a><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f689682c6\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"background-color: #ffffff; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 38px;color: #222222;line-height: 44px;text-align: left\" >Power Quality Monitoring<\/h2><\/div><div class=\"codeless_separator\" style=\" height:2px; \"><span class=\"separator\" style=\" width:70px;  background:#ffdd00;  left:0; height:100%; position:absolute;\"><\/span><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f6896899b\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"background-color: #ffffff; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>Power Quality Monitors<\/p>\n\n\t\t<\/div> \n\t<\/div> <div class=\"wpb_content_element list\" style=\"\"><ul data-icon=\"steadysets-icon-checkmark\">\n\t\t\t\t<li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Power Quality<\/h6><p>Class A with extended features<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Disturbance<\/h6><p>1\/2 Period storing &amp; triggering<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>System Dynamics<\/h6><p>Resonances, Phase Angle Jumps, etc.<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Transient Recording<\/h6><p>Waveform &amp; Disturbance Trigger<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Phasor Measurement Unit (PMU)<\/h6><p>Wide Area Monitoring System (WAMS)<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>RoCoF<\/h6><p>Rate of Change of Frequency<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Energy Measurement<\/h6><p>Multi-Feeder<\/p><\/dd><\/dl><\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>PQ SCADA Software<\/p>\n\n\t\t<\/div> \n\t<\/div> <div class=\"wpb_content_element list\" style=\"\"><ul data-icon=\"steadysets-icon-checkmark\">\n\t\t\t\t<li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Visualisations<\/h6><p>Recorder, Waveform, FFT, Vector, Table, etc.<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Report<\/h6><p>EN50160, IEEE519, IEC61000-2-4, etc.<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Statistics<\/h6><p>for substations, areas, states<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Maps<\/h6><p>Geographical Visualisation<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Interfaces<\/h6><p>IEC61850\/60870-5-104\/Modbus<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Redundancy<\/h6><p>local and centralised data storage<\/p><\/dd><\/dl><\/li><li class=\"titledesc\"><dl class=\"dl-horizontal\"><dt><span class=\"circle\"><i class=\"\"><\/i><\/span><\/dt><dd><h6>Remote Configuration<\/h6><p>and Supervision<\/p><\/dd><\/dl><\/li><\/ul><\/div><\/div><\/div><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/overview.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_left\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f6896bd19\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     \" style=\"background-color: #f9f9f9; padding-bottom: 0px ; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 36px;color: #1c1c1c;text-align: center\" >Key Features<\/h2><\/div><div class=\"codeless_separator\" style=\" height:1px;  margin-top:0px;  margin-bottom:35px; \"><span class=\"separator\" style=\" width:60px;  background:#ffdd00;  left:50%;height:100%; margin-left: -30px;position: absolute;\"><\/span><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f6896c3e8\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section     \" style=\"\" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_tta-container\" data-vc-action=\"collapseAll\"><div class=\"vc_general vc_tta vc_tta-accordion vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-o-shape-group vc_tta-controls-align-default vc_tta-o-all-clickable\"><div class=\"vc_tta-panels-container\"><div class=\"vc_tta-panels\"><div class=\"vc_tta-panel vc_active\" id=\"1611731691834-93b57d68-680f\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1611731691834-93b57d68-680f\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Power Quality<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\"><div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/power_quality.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_left\" \/><\/div><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><em>according to IEC 61000-4-30 Ed.3 and IEC 62586<\/em><\/p>\n<p><strong>Harmonics, Interharmonics and THD<\/strong>:<br \/>\nClass A<br \/>\n<strong>Higher Frequencies (200Hz band):<\/strong><br \/>\n2 &#8211; 9 kHz<br \/>\n<strong>Symmetrical Components &amp; Unbalance<\/strong>:<br \/>\nClass A ((Pos-, Neg- and Zero Sequence))<br \/>\n<strong>Flicker (PST, PLT, Pinst) and RVC:<\/strong><br \/>\nClass A<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>.<\/p>\n<p><strong>Voltage Events<\/strong>:<br \/>\nClass A (dip, swell, interruption \u2013 time, extrema, length)<br \/>\n<strong>Frequency:<\/strong><br \/>\n10 sec, AVE, MIN, MAX<br \/>\n<strong>Voltage, Current:<br \/>\n<\/strong>RMS, AVE, MIN, MAX, \u00bd Period-values, 200ms, 10s, 10min<br \/>\n<strong>Time Synchronisation:<\/strong><br \/>\nClass A<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_tta-panel\" id=\"1611731691905-9e90599b-de5f\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1611731691905-9e90599b-de5f\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Power<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\"><div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/power_4.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_left\" \/><\/div><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>Power Calculation:<br \/>\n<\/strong>P, Q, S, PF, cos phi, D, DH, QH<\/p>\n<p><strong>Frequency:<br \/>\n<\/strong>10 sec, AVE, MIN, MAX<\/p>\n<p><strong>Voltage, Current:<br \/>\n<\/strong>RMS, AVE, MIN, MAX, \u00bd Period-values, 200ms, 10s, 10min<\/p>\n<p><strong>Power Calculation:<br \/>\n<\/strong>P, Q, S, PF, cos phi, D, DH, QH<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>Energy:<br \/>\n<\/strong>Total, positive, negative (P, Q, P+, P-, Q+, Q-)<\/p>\n<p><strong>Efficiency:<br \/>\n<\/strong>DC \/ AC, U-I Curve for PV<\/p>\n<p><strong>Wiring:<\/strong><br \/>\nDC, 1-Phase, 2-Phase, 3-Phase Star and Delta<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_tta-panel\" id=\"1611732018865-548ad9dc-83a2\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1611732018865-548ad9dc-83a2\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Waveform &amp; Transients<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\"><div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/waveform.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_left\" \/><\/div><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>MIN, MAX, RMS, AVE:<br \/>\n<\/strong>U, I, P, Q, S, f, PF, phi, THD, Harmonics, Interharm., Unbalance, etc.<br \/>\n<strong>ENVELOPE \/ WINDOW:<br \/>\n<\/strong>U, I<br \/>\n<strong>DELTA:<br \/>\n<\/strong>dU, dI, df, dP, etc.<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>DERIVATE (RATE OF CHANGE):<br \/>\n<\/strong>dU\/dt, df\/dt etc. \u2026 per ms, number of periods or half-period<br \/>\n<strong>VOLTAGE SIGNALLING:<br \/>\n<\/strong>Threshold<br \/>\n<strong>EN50160:<br \/>\n<\/strong>Trigger on any EN50160 parameter (Max, Quantil)<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_tta-panel\" id=\"1611732198504-bb20280b-ab8c\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1611732198504-bb20280b-ab8c\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Disturbances and System Dynamics<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\"><div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/disturbance_pqm.png\" alt=\"Alt Text\" class=\"type_image animated fadeInLeft alignment_left\" \/><\/div><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>1\/2 PERIOD TRIGGER:<\/strong><br \/>\nU, I, P, Q, S, f, PF, phi, THD, Harmonics, Interharm., Unbalance, etc.<\/p>\n<p><strong>SYMMETRICAL COMPONENTS:<\/strong><br \/>\nPositive-, Negative-, Zerosequence<\/p>\n<p><strong>Phasor Measurement Unit (PMU)<\/strong><br \/>\naccording to IEEE C37.118: Total Vector Error 0.01% (typ.), Angle Error 0.003\u00b0(typ)<\/p>\n<p><strong>RATE OF CHANGE FREQUENCY (ROCOF)<\/strong><\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><div class=\"vc_tta-panel\" id=\"1611732276856-a51ae21d-9657\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1611732276856-a51ae21d-9657\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Complying Standards<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>POWER QUALITY, HARMONICS, FLICKER:<\/strong><br \/>\nIEC61000-4-30 Ed. 3 Class A \/ IEC61000-4-7 \/ IEC61000-4-15 \/\u00a0 IEC62586-2 Ed. 2 \/ IEC62586-1<br \/>\n<strong>PUBLIC GRID, RAILWAY AND INDUSTRY<\/strong><br \/>\nEN50160 \/ EN50163 \/ IEC61000-2-2 \/ IEC61000-2-4 (Class 1; 2; 3) \/ IEEE519\u00a0 \/ IEEE 1159 \/ IEC61000-2-12 \/ NRS048<br \/>\n<strong>WIND POWER, RENEWABLES AND GRID CODES<\/strong><br \/>\nIEC61400-21 \/ IEC61400-12 \/ FGW-TR3 \/ VDE N-4105 \/ VDE N-4100 \/ VDE N-4110 \/ D-A-CH-CZ \/ BDEW \/ ROCOF \/ IEEE C37.118-2005 (PMU)<br \/>\n<strong>MOTORS, TRANSFORMERS AND ELECTRICAL EQUIPMENT<\/strong><br \/>\nIEC60034 \/ IEC 60076-1 \/ IEC61000-3-2 \/ IEC61000-3-3 \/ IEC61000-3-11 \/ IEC61000-3-12<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><\/div><\/div><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t\n\t\t<\/div> \n\t<\/div> \n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f68975d17\" class=\"vc_row wpb_row vc_row-fluid   row-dynamic-el section-style parallax_section mobile_parallax_section    \" style=\"background-repeat: no-repeat; padding-top: 120px ; padding-bottom: 120px ;  background-image: url(https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/wind_trans_45-scaled.jpg); background-position: 50% 0px; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"bg-overlay\" style=\"background:rgba(34,34,34,0.8 );\"><\/div><div class=\"container animate_onoffset light\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 38px;color: #ffffff;line-height: 44px;text-align: center\" >APPLICATIONS<\/h2><\/div><div class=\"codeless_separator\" style=\" height:2px;  margin-top:-15px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:70px;  background:#ffdd00;  left:50%;height:100%; margin-left: -35px;position: absolute;\"><\/span><\/div><div class=\"textbar style_2 wpb_content_element \"><h2>See all Applications of the NEO PQ Analyzers<\/h2><a href=\"https:\/\/www.neo-messtechnik.com\/hestia\/applications\" class=\"btn-bt default\"><span>Applications<\/span><i class=\"linecon-icon-world\"><\/i><\/a><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a14f68976736\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section     \" style=\"background-color: #c6c6c6; padding-top: 20px ; padding-bottom: 20px ; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-6 wpb_column column_container vc_custom_1587805963444  vc_custom_1587805963444\" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"text-align: left\" >Datasheet<\/h2><\/div>\n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"wpb_content_element button \"><a  class=\"btn-bt align-left default\" href=\"https:\/\/www.neo-messtechnik.com\/downloads\"><span>DOWNLOADS<\/span><i class=\"moon-file-pdf\"><\/i><\/a><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"PQM 100 ACCURACY0.1%RESOLUTION24bitSAMPLING16 kS\/s or 32 kS\/s SAFETYCAT IV 300VMODULAR SYSTEMup to 64 chDYNAMIC0,5A to 1,5A HardwareState of the Art Hybrid Data StorageEven if connection is lost, all data is stored locally and will be transferred after reconnection. Data on demandAll data can be transferred continuously or just triggered on demand. Remote ConfigurationThe instrument can [...]","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-5405","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PQM 100 - NEO Messtechnik<\/title>\n<meta name=\"description\" content=\"Modular architecture, hybrid data storage and remote configuration - the PQM100 covers all your Monitoring needs.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.neo-messtechnik.com\/en\/pqm-100\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PQM 100 - NEO Messtechnik\" \/>\n<meta property=\"og:description\" content=\"Modular architecture, hybrid data storage and remote configuration - the PQM100 covers all your Monitoring needs.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.neo-messtechnik.com\/en\/pqm-100\" \/>\n<meta property=\"og:site_name\" content=\"NEO Messtechnik\" \/>\n<meta property=\"article:modified_time\" content=\"2021-02-16T11:24:54+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/pqm-100\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/pqm-100\",\"name\":\"PQM 100 - NEO Messtechnik\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\"},\"datePublished\":\"2020-04-11T16:21:11+00:00\",\"dateModified\":\"2021-02-16T11:24:54+00:00\",\"description\":\"Modular architecture, hybrid data storage and remote configuration - the PQM100 covers all your Monitoring needs.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/pqm-100#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/pqm-100\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/pqm-100#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PQM 100\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"name\":\"NEO Messtechnik\",\"description\":\"Power Quality with perfection\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\",\"name\":\"NEO Messtechnik GmbH\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"contentUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"width\":466,\"height\":264,\"caption\":\"NEO Messtechnik GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/linkedin.com\\\/company\\\/neo-messtechnik\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PQM 100 - NEO Messtechnik","description":"Modular architecture, hybrid data storage and remote configuration - the PQM100 covers all your Monitoring needs.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.neo-messtechnik.com\/en\/pqm-100","og_locale":"en_US","og_type":"article","og_title":"PQM 100 - NEO Messtechnik","og_description":"Modular architecture, hybrid data storage and remote configuration - the PQM100 covers all your Monitoring needs.","og_url":"https:\/\/www.neo-messtechnik.com\/en\/pqm-100","og_site_name":"NEO Messtechnik","article_modified_time":"2021-02-16T11:24:54+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.neo-messtechnik.com\/en\/pqm-100","url":"https:\/\/www.neo-messtechnik.com\/en\/pqm-100","name":"PQM 100 - NEO Messtechnik","isPartOf":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#website"},"datePublished":"2020-04-11T16:21:11+00:00","dateModified":"2021-02-16T11:24:54+00:00","description":"Modular architecture, hybrid data storage and remote configuration - the PQM100 covers all your Monitoring needs.","breadcrumb":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/pqm-100#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.neo-messtechnik.com\/en\/pqm-100"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.neo-messtechnik.com\/en\/pqm-100#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.neo-messtechnik.com\/"},{"@type":"ListItem","position":2,"name":"PQM 100"}]},{"@type":"WebSite","@id":"https:\/\/www.neo-messtechnik.com\/en\/#website","url":"https:\/\/www.neo-messtechnik.com\/en\/","name":"NEO Messtechnik","description":"Power Quality with perfection","publisher":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.neo-messtechnik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization","name":"NEO Messtechnik GmbH","url":"https:\/\/www.neo-messtechnik.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","contentUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","width":466,"height":264,"caption":"NEO Messtechnik GmbH"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/linkedin.com\/company\/neo-messtechnik"]}]}},"_links":{"self":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/pages\/5405","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/comments?post=5405"}],"version-history":[{"count":46,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/pages\/5405\/revisions"}],"predecessor-version":[{"id":6314,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/pages\/5405\/revisions\/6314"}],"wp:attachment":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/media?parent=5405"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}