{"id":4764,"date":"2020-03-12T16:34:51","date_gmt":"2020-03-12T15:34:51","guid":{"rendered":"https:\/\/www.neo-messtechnik.com\/hestia\/?page_id=4764"},"modified":"2021-02-16T12:53:25","modified_gmt":"2021-02-16T11:53:25","slug":"pq-management-scada","status":"publish","type":"page","link":"https:\/\/www.neo-messtechnik.com\/en\/pq-management-scada","title":{"rendered":"Power Quality Management SCADA"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div id=\"fws_69de73817594d\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section  overview   wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"\" ><div id=\"overview\" style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading vc_custom_1613475348380 wpb_content_element\" ><h1 style=\"font-size: 38px;line-height: 44px;text-align: left\" >Power Quality SCADA<\/h1><\/div><div class=\"codeless_separator\" style=\" height:4px;  margin-top:0px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:40px;  background:#fde328;  left:0; height:100%; position:absolute;\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"wpb_content_element list\" style=\"\"><ul data-icon=\"moon-checkbox\">\n\t\t\t\t<li class=\"simple\"><i class=\"\"><\/i>Real Time &amp; Historical Data<\/li><li class=\"simple\"><i class=\"\"><\/i>Multiple Visualisation<\/li><li class=\"simple\"><i class=\"\"><\/i>Automatic Report Generation (EN50160)<\/li><\/ul><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"wpb_content_element list\" style=\"\"><ul data-icon=\"moon-checkbox\">\n\t\t\t\t<li class=\"simple\"><i class=\"\"><\/i>Notifications, Alarm, Email, SMS<\/li><li class=\"simple\"><i class=\"\"><\/i>Remote Meter Configuration<\/li><li class=\"simple\"><i class=\"\"><\/i>User Management tool<\/li><\/ul><\/div><\/div><\/div><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/scada_transparent.png\" alt=\"Alt Text\" class=\"type_image animated fadeInLeft alignment_left\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_69de7381794fc\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section  overview   wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"\" ><div id=\"overview\" style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading vc_custom_1584026865950 wpb_content_element\" ><h2 style=\"text-align: left\" >OVERVIEW<\/h2><\/div><div class=\"codeless_separator\" style=\" height:4px;  margin-top:0px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:40px;  background:#fde328;  left:0; height:100%; position:absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>PQM-SCADA is the enterprise management software for Power Quality Analyzers and Disturbance Recorders. It is an easy-to-use software solution that allows the user to visualize live-data, historical data or reports. The multi-screen capability gives the user the ability to design their own visualization screens including the use of multiple monitors.<\/p>\n<p>User-management with different access and security levels is integrated, including to give your customers access to view limited data. The following picture shows the Overview &amp; Configuration menu.<\/p>\n\n\t\t<\/div> \n\t<\/div> \n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/schemata_pqm_scada.png\" alt=\"Alt Text\" class=\"type_image animated fadeInLeft alignment_left\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_69de73817b951\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section  overview   wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"\" ><div id=\"overview\" style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading vc_custom_1584027561393 wpb_content_element\" ><h2 style=\"text-align: left\" >CONNECTIVITY &amp; INTERFACES<\/h2><\/div><div class=\"codeless_separator\" style=\" height:4px;  margin-top:0px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:40px;  background:#fde328;  left:0; height:100%; position:absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>The PQM-SCADA system can communicate with other systems and also provides data to any third party system. The User Management tool allows an unlimited number of users to be added with different access and security levels.<\/p>\n\n\t\t<\/div> \n\t<\/div> \n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_69de73817c50c\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section     wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"\" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading vc_custom_1584027075272 wpb_content_element\" ><h2 style=\"text-align: left\" >LIVE DATA<\/h2><\/div><div class=\"codeless_separator\" style=\" height:4px;  margin-top:0px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:40px;  background:#fde328;  left:0; height:100%; position:absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>All visualizations are flexible and can be easily configured (parameters, colors, etc.). All graphs can be shown simultaneously.<\/p>\n\n\t\t<\/div> \n\t<\/div> <div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/pqm_scada_online.png\" alt=\"Alt Text\" class=\"type_image animated fadeInLeft alignment_left\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading vc_custom_1584026099504 wpb_content_element\" ><h2 style=\"text-align: left\" >HISTORY DATA<\/h2><\/div><div class=\"codeless_separator\" style=\" height:4px;  margin-top:0px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:40px;  background:#fde328;  left:0; height:100%; position:absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>The powerful analysis capabilities allows for comprehensive data analysis inside the enterprise software.<\/p>\n\n\t\t<\/div> \n\t<\/div> <div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/pqm_scada_history-data.png\" alt=\"Alt Text\" class=\"type_image animated fadeInLeft alignment_left\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_69de738180563\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section  overview   wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"\" ><div id=\"overview\" style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading vc_custom_1584026360772 wpb_content_element\" ><h2 style=\"text-align: left\" >ADDITIONAL FEATURES<\/h2><\/div><div class=\"codeless_separator\" style=\" height:4px;  margin-top:0px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:40px;  background:#fde328;  left:0; height:100%; position:absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>There are additional features such as alarms, notifications, emails and SMS services. All PQM and PQA meters can be configured remotely (firmware, software, configuration etc.). This powerful system monitors each device status and its fault state. The supervision overview distinguishes between two states: OK and Failed. Some of the functions available for monitoring include: ping, sw running, data storing, data in the database, etc.<\/p>\n\n\t\t<\/div> \n\t<\/div> \n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_69de73818103d\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section  overview   wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"\" ><div id=\"overview\" style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading vc_custom_1611735248983 wpb_content_element\" ><h2 style=\"text-align: left\" >PMU - PHASOR MEASUREMENT UNIT<\/h2><\/div><div class=\"codeless_separator\" style=\" height:4px;  margin-top:0px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:40px;  background:#fde328;  left:0; height:100%; position:absolute;\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>Highest Precision Synchrophasor Measurement<\/strong><\/p>\n<p>PMU &#8211; The Phasor Measurement Unit is a device for accurate synchrophasor measurements. The measurement results are used for the online detection of the electrical grid status. This principle is based on comparing the phase angles of the fundamental harmonic measured at different points of the distribution or transmission network using several devices at synchronized points in time.<br \/>\n<em>High-Accurate GPS Receiver<\/em><br \/>\nThe meter has to be equipped by the internal\/external GPS for receiving synchronous timestamps.<br \/>\n<em>Additional Sensor and Range calibration<\/em><br \/>\nThe additional sensor and measurement range calibration (see chapter PQA8000 calibration) allows for highly accurate measurement results<em>.<\/em><\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>I<em>EEE C37.118<\/em><br \/>\nThe PMU firmware measures voltage and current phasors, frequency, and calculates the positive symmetrical components of voltages and currents. The measured data is sent to the superior system according to the IEEE C37.118 communication protocol. By default, the device fully complies with the requirements of IEEE C37.118, which defines the PMU accuracy in stabilized state and a communication protocol for real-time phasor transmission.<\/p>\n<p>The PQA8000 instrument offers a built-in GPS receiver together with highly-accurate voltage inputs and<br \/>\n&#8211; Total Vector Error 0.01% (typ.)<br \/>\n&#8211; Angle Accuracy 0.003\u00b0 (typ.)<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_69de738182d54\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section  overview   wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"\" ><div id=\"overview\" style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading vc_custom_1584025086738 wpb_content_element\" ><h2 style=\"text-align: left\" >WAMS - Wide Area Monitoring System<\/h2><\/div><div class=\"codeless_separator\" style=\" height:4px;  margin-top:0px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:40px;  background:#fde328;  left:0; height:100%; position:absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>Phasor angle differences between various parts of the transmission grid are an indicator of grid health and can provide early warning in the case of developing power system disturbances that can lead to grid separation known as islanding, or even blackout. The accurate measurement of the phasor angles across the grid is made possible by the use of GPS-synchronized phasor-sampling clocks. Nationwide networks of time-synchronized phasor measurement units (PMUs) are called Wide Area Monitoring Systems (WAMS).<\/p>\n<p>The main features of the WAMS systems are the visualization and monitoring of phasors , islanding detection, resynchronization and black start detection, oscillations detection, stability and voltage monitoring. The results can also be passed to SCADA or other systems.<\/p>\n\n\t\t<\/div> \n\t<\/div> \n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_separator wpb_content_element vc_separator_align_center vc_sep_width_100 vc_sep_pos_align_center vc_separator_no_text vc_sep_color_white wpb_content_element  wpb_content_element\" ><span class=\"vc_sep_holder vc_sep_holder_l\"><span class=\"vc_sep_line\"><\/span><\/span><span class=\"vc_sep_holder vc_sep_holder_r\"><span class=\"vc_sep_line\"><\/span><\/span>\n<\/div><div class=\"codeless_separator\" style=\" height:55px;  margin-top:0px;  margin-bottom:0px; \"><span class=\"separator\" style=\" width:40px;  left:50%;height:100%; margin-left: -20px;position: absolute;\"><\/span><\/div><div class=\"wpb_content_element media_align_center media media_el animate_onoffset \"><div class=\"media_wrapper\" style=\"width:500px;position:relative; left:50%; margin-left:-250px;\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/PQM-SCADA-scaled.jpg\" alt=\"Alt Text\" class=\"type_image animated fadeInLeft alignment_center\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_69de738186227\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section  overview   wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"\" ><div id=\"overview\" style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading vc_custom_1584025328524 wpb_content_element\" ><h2 style=\"text-align: left\" >ENERGY MEASUREMENT<\/h2><\/div><div class=\"codeless_separator\" style=\" height:4px;  margin-top:0px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:40px;  background:#fde328;  left:0; height:100%; position:absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>Meter input modules are designed to measure one 3-phase voltage and multiple 3-phase current systems. The intention of this meter is typically to monitor the distribution transformer powering multiple output feeders. The functionality of multi-feeder-monitors is similar to a PQ meter, with the possibility of measuring up to 10x the number of 3-phase feeders in total. The multi-feeder-monitor also provides detailed information about the power and energy consumption of each feeder<\/p>\n\n\t\t<\/div> \n\t<\/div> \n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_separator wpb_content_element vc_separator_align_center vc_sep_width_100 vc_sep_pos_align_center vc_separator_no_text vc_sep_color_white wpb_content_element  wpb_content_element\" ><span class=\"vc_sep_holder vc_sep_holder_l\"><span class=\"vc_sep_line\"><\/span><\/span><span class=\"vc_sep_holder vc_sep_holder_r\"><span class=\"vc_sep_line\"><\/span><\/span>\n<\/div><div class=\"codeless_separator\" style=\" height:55px;  margin-top:0px;  margin-bottom:0px; \"><span class=\"separator\" style=\" width:40px;  left:50%;height:100%; margin-left: -20px;position: absolute;\"><\/span><\/div><div class=\"wpb_content_element media_align_center media media_el animate_onoffset \"><div class=\"media_wrapper\" style=\"width:500px;position:relative; left:50%; margin-left:-250px;\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/2_4_Energy.png\" alt=\"Alt Text\" class=\"type_image animated fadeInLeft alignment_center\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_69de7381893da\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section  overview   wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"\" ><div id=\"overview\" style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading vc_custom_1588238632048 wpb_content_element\" ><h2 style=\"text-align: left\" >NEO Power Quality Monitors<\/h2><\/div><div class=\"codeless_separator\" style=\" height:4px;  margin-top:0px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:40px;  background:#fde328;  left:0; height:100%; position:absolute;\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid vc_row-o-content-middle vc_row-flex\"><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_custom_heading vc_custom_1588238002244 wpb_content_element\" ><h3 style=\"text-align: left\" >PQM100<\/h3><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>Accuracy:\u00a0\u00a0<\/strong> \u00a0\u00a0 0.1%<br \/>\n<strong>Sampling:<\/strong> \u00a0\u00a0\u00a0 16 kS\/s or 32 kS\/s<br \/>\n<strong>Resolution:<\/strong>\u00a0 24bit<br \/>\n<strong>Safety:<\/strong> \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 CAT IV 600V<\/p>\n\n\t\t<\/div> \n\t<\/div> <div class=\"vc_btn3-container vc_btn3-center vc_do_btn\" ><a class=\"vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-modern vc_btn3-color-grey\" href=\"https:\/\/www.neo-messtechnik.com\/pqm-100\" title=\"PQM 100\">View More<\/a><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"wpb_content_element media_align_center media media_el animate_onoffset \"><div class=\"media_wrapper\" style=\"width:170px;position:relative; left:50%; margin-left:-85px;\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/pqm100_slide.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_center\" \/><\/div><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_custom_heading vc_custom_1588238318532 wpb_content_element\" ><h3 style=\"text-align: left\" >PQM200<\/h3><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>Accuracy:\u00a0\u00a0<\/strong> \u00a0\u00a0 0.05%<br \/>\n<strong>Sampling:<\/strong> \u00a0\u00a0\u00a0 124 kS\/s<br \/>\n<strong>Resolution:<\/strong>\u00a0 24bit<br \/>\n<strong>Safety:<\/strong> \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 CAT IV 600V<\/p>\n\n\t\t<\/div> \n\t<\/div> <div class=\"vc_btn3-container vc_btn3-center vc_do_btn\" ><a class=\"vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-modern vc_btn3-color-grey\" href=\"https:\/\/www.neo-messtechnik.com\/pqm200-2\" title=\"PQM 200\">View More<\/a><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-3\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"wpb_content_element media_align_center media media_el animate_onoffset \"><div class=\"media_wrapper\" style=\"width:220px;position:relative; left:50%; margin-left:-110px;\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/pqm200_slide.png\" alt=\"Alt Text\" class=\"type_image animated fadeInLeft alignment_center\" \/><\/div><\/div><\/div><\/div><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"Power Quality SCADA Real Time &amp; Historical DataMultiple VisualisationAutomatic Report Generation (EN50160) Notifications, Alarm, Email, SMSRemote Meter ConfigurationUser Management tool OVERVIEW PQM-SCADA is the enterprise management software for Power Quality Analyzers and Disturbance Recorders. It is an easy-to-use software solution that allows the user to visualize live-data, historical data or reports. The multi-screen capability gives [...]","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-4764","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Power Quality Management SCADA - NEO Messtechnik<\/title>\n<meta name=\"description\" content=\"PQM-SCADA is the enterprise management software for Real-time and Historical data, stored on a central server or cloud storage.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.neo-messtechnik.com\/en\/pq-management-scada\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Power Quality Management SCADA - NEO Messtechnik\" \/>\n<meta property=\"og:description\" content=\"PQM-SCADA is the enterprise management software for Real-time and Historical data, stored on a central server or cloud storage.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.neo-messtechnik.com\/en\/pq-management-scada\" \/>\n<meta property=\"og:site_name\" content=\"NEO Messtechnik\" \/>\n<meta property=\"article:modified_time\" content=\"2021-02-16T11:53:25+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/pq-management-scada\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/pq-management-scada\",\"name\":\"Power Quality Management SCADA - NEO Messtechnik\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\"},\"datePublished\":\"2020-03-12T15:34:51+00:00\",\"dateModified\":\"2021-02-16T11:53:25+00:00\",\"description\":\"PQM-SCADA is the enterprise management software for Real-time and Historical data, stored on a central server or cloud storage.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/pq-management-scada#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/pq-management-scada\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/pq-management-scada#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Power Quality Management SCADA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"name\":\"NEO Messtechnik\",\"description\":\"Power Quality with perfection\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\",\"name\":\"NEO Messtechnik GmbH\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"contentUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"width\":466,\"height\":264,\"caption\":\"NEO Messtechnik GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/linkedin.com\\\/company\\\/neo-messtechnik\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Power Quality Management SCADA - NEO Messtechnik","description":"PQM-SCADA is the enterprise management software for Real-time and Historical data, stored on a central server or cloud storage.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.neo-messtechnik.com\/en\/pq-management-scada","og_locale":"en_US","og_type":"article","og_title":"Power Quality Management SCADA - NEO Messtechnik","og_description":"PQM-SCADA is the enterprise management software for Real-time and Historical data, stored on a central server or cloud storage.","og_url":"https:\/\/www.neo-messtechnik.com\/en\/pq-management-scada","og_site_name":"NEO Messtechnik","article_modified_time":"2021-02-16T11:53:25+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.neo-messtechnik.com\/en\/pq-management-scada","url":"https:\/\/www.neo-messtechnik.com\/en\/pq-management-scada","name":"Power Quality Management SCADA - NEO Messtechnik","isPartOf":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#website"},"datePublished":"2020-03-12T15:34:51+00:00","dateModified":"2021-02-16T11:53:25+00:00","description":"PQM-SCADA is the enterprise management software for Real-time and Historical data, stored on a central server or cloud storage.","breadcrumb":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/pq-management-scada#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.neo-messtechnik.com\/en\/pq-management-scada"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.neo-messtechnik.com\/en\/pq-management-scada#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.neo-messtechnik.com\/"},{"@type":"ListItem","position":2,"name":"Power Quality Management SCADA"}]},{"@type":"WebSite","@id":"https:\/\/www.neo-messtechnik.com\/en\/#website","url":"https:\/\/www.neo-messtechnik.com\/en\/","name":"NEO Messtechnik","description":"Power Quality with perfection","publisher":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.neo-messtechnik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization","name":"NEO Messtechnik GmbH","url":"https:\/\/www.neo-messtechnik.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","contentUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","width":466,"height":264,"caption":"NEO Messtechnik GmbH"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/linkedin.com\/company\/neo-messtechnik"]}]}},"_links":{"self":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/pages\/4764","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/comments?post=4764"}],"version-history":[{"count":22,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/pages\/4764\/revisions"}],"predecessor-version":[{"id":6777,"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/pages\/4764\/revisions\/6777"}],"wp:attachment":[{"href":"https:\/\/www.neo-messtechnik.com\/en\/wp-json\/wp\/v2\/media?parent=4764"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}