{"id":10521,"date":"2026-04-07T18:07:24","date_gmt":"2026-04-07T16:07:24","guid":{"rendered":"https:\/\/www.neo-messtechnik.com\/?page_id=10521"},"modified":"2026-04-27T10:01:24","modified_gmt":"2026-04-27T08:01:24","slug":"pqa-8000h-rack-mount-power-quality-analyzer","status":"publish","type":"page","link":"https:\/\/www.neo-messtechnik.com\/de\/pqa-8000h-rack-mount-power-quality-analyzer","title":{"rendered":"PQA 8000H Rack Mount Power Quality Analyzer"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div id=\"fws_6a19ca9bbbfea\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section     \" style=\"\" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a19ca9bbcabb\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"background-color: #F6F6F6; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 40px;text-align: left\" >The Premium Device for Professional Monitoring<\/h2><\/div><div class=\"codeless_separator\" style=\" height:2px;  margin-top:-15px;  margin-bottom:20px; \"><span class=\"separator\" style=\" width:70px;  background:#ffdd00;  left:0; height:100%; position:absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>With the new PQA 8000H-RM, NEO Messtechnik brings the full measurement capability of the <a href=\"https:\/\/www.neo-messtechnik.com\/pqa8000\">PQA 8000H<\/a> into a 19&#8243; rackmount form factor \u2014 designed for permanent installation in substations, battery energy storage systems, and grid-connected infrastructure. The instrument retains all hardware and software capabilities of its portable variant, while adding a higher-performance processor and up to four integrated IPCS 10A Zeroflux sensors.<\/p>\n<p>Without display or battery, the PQA 8000H-RM is purpose-built for headless, continuous operation and remote access.<\/p>\n\n\t\t<\/div> \n\t<\/div> \n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a19ca9bbdcff\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"background-color: #ffffff; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2026\/04\/PQA8000H-Rackmount_Back.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_left\" \/><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n\n\t<div class=\"vc_col-sm-6 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<ul>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Accuracy:<\/strong> 0.05% \/ 0.01% (PMU)<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Sampling Rate:<\/strong> 1 MS\/s,\u00a0<strong>Resolution:<\/strong> 18 bit<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Supraharmonics:<\/strong> up to 500 kHz<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Voltage Inputs:<\/strong> 4x, up to 800 V \/ 1600 V<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Current Inputs:<\/strong> up to 8x (Rogowski, Clamp AC\/DC, Zeroflux)<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Dynamic Range:<\/strong> 0.5 mA to 150 kA (15 ranges)<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Isolation:<\/strong> 6 kV (CH\u2013GND)<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Safety:<\/strong> CAT III 1000V \/ CAT IV 600V<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Interfaces:<\/strong> LAN \/ WLAN \/ LTE \/ Bluetooth \/ GPS \/ CAN \/ RS485 \/ Digital IO<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>Power Quality Class:<\/strong> A++ \u2014 exceeds IEC61000-4-30 Ed.3 and Ed.4<\/li>\n<li class=\"whitespace-normal break-words pl-2\"><strong>PMU:<\/strong> IEC\/IEEE 60255-118-1, TVE \u2264 0.01%, angle error \u2264 0.003\u00b0<\/li>\n<\/ul>\n\n\t\t<\/div> \n\t<\/div> \n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a19ca9bbfda3\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"background-color: #F6F6F6; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 36px;color: #1c1c1c;text-align: center\" >Hardware Highlights<\/h2><\/div><div class=\"codeless_separator\" style=\" height:1px;  margin-top:0px;  margin-bottom:35px; \"><span class=\"separator\" style=\" width:60px;  background:#ffdd00;  left:50%;height:100%; margin-left: -30px;position: absolute;\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid vc_custom_1737034526431 vc_row-has-fill\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\" services_small wpb_content_element align_right\"><dl class=\"dl-horizontal with_icon\">    <dt><div class=\"wrapper\" style=\"background:#ffdd00;\">        <i class=\"steadysets-icon-cube\" style=\"color:#ffffff;\"><\/i><\/div>    <\/dt>    <dd>        <h4><a href=\"\">Permanent Installation<\/a><\/h4>    <div class=\"content\">         <div>19\u2033 rack mount form factor for substations, control cabinets, and infrastructure environments. No display, no battery \u2014 built for continuous unattended operation.<\/p>\n<p><\/div>    <\/div>    <\/dd><\/dl><\/div><div class=\" services_small wpb_content_element align_right\"><dl class=\"dl-horizontal with_icon\">    <dt><div class=\"wrapper\" style=\"background:#ffdd00;\">        <i class=\"steadysets-icon-atom\" style=\"color:#ffffff;\"><\/i><\/div>    <\/dt>    <dd>        <h4><a href=\"\">Higher-Performance Processor<\/a><\/h4>    <div class=\"content\">         <div>More computing power than the portable PQA 8000, enabling faster real-time processing and simultaneous high-resolution data streams.<\/div>    <\/div>    <\/dd><\/dl><\/div><div class=\" services_small wpb_content_element align_right\"><dl class=\"dl-horizontal with_icon\">    <dt><div class=\"wrapper\" style=\"background:#ffdd00;\">        <i class=\"steadysets-icon-bolt\" style=\"color:#ffffff;\"><\/i><\/div>    <\/dt>    <dd>        <h4><a href=\"\">Up to 4x Integrated Zeroflux Sensors<\/a><\/h4>    <div class=\"content\">         <div>IPCS 10A Zeroflux current sensors included \u2014 highest accuracy AC\/DC current measurement, directly powered by the instrument.<\/p>\n<p><\/div>    <\/div>    <\/dd><\/dl><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\" services_small wpb_content_element align_left\"><dl class=\"dl-horizontal with_icon\">    <dt><div class=\"wrapper\" style=\"background:#ffdd00;\">        <i class=\"moon-clock-3\" style=\"color:#ffffff;\"><\/i><\/div>    <\/dt>    <dd>        <h4><a href=\"\">GPS Time Synchronisation<\/a><\/h4>    <div class=\"content\">         <div>Highly precise UTC-referenced time stamping \u2014 fundamental to PMU synchrophasor measurements and wide-area monitoring applications.<\/div>    <\/div>    <\/dd><\/dl><\/div><div class=\" services_small wpb_content_element align_left\"><dl class=\"dl-horizontal with_icon\">    <dt><div class=\"wrapper\" style=\"background:#ffdd00;\">        <i class=\"steadysets-icon-newspaper\" style=\"color:#ffffff;\"><\/i><\/div>    <\/dt>    <dd>        <h4><a href=\"\">Up to 1 TB SSD Storage<\/a><\/h4>    <div class=\"content\">         <div>Continuous raw data recording at full 1 MS\/s sampling rate. Local storage combined with remote access via LAN, WLAN, or LTE.<\/div>    <\/div>    <\/dd><\/dl><\/div><div class=\" services_small wpb_content_element align_left\"><dl class=\"dl-horizontal with_icon\">    <dt><div class=\"wrapper\" style=\"background:#ffdd00;\">        <i class=\"steadysets-icon-diamond\" style=\"color:#ffffff;\"><\/i><\/div>    <\/dt>    <dd>        <h4><a href=\"\">Remote Access<\/a><\/h4>    <div class=\"content\">         <div>No on-site presence required for configuration, monitoring, or data retrieval.<\/div>    <\/div>    <\/dd><\/dl><\/div><\/div><\/div><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 10px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><div class=\"vc_btn3-container vc_btn3-center vc_do_btn\" ><a class=\"vc_general vc_btn3 vc_btn3-size-md vc_btn3-shape-rounded vc_btn3-style-modern vc_btn3-color-grey\" href=\"https:\/\/www.neo-messtechnik.com\/wide-area-monitoring-systems-wams\" title=\"Wide Area Monitoring Systems (WAMS)\">Perfect fit for the Wide Area Monitoring via SmartGRID EDGE PDC!<\/a><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a19ca9bc20bd\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"background-color: #FFFFFF; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 36px;color: #1c1c1c;text-align: center\" >Software Highlights<\/h2><\/div><div class=\"codeless_separator\" style=\" height:1px;  margin-top:0px;  margin-bottom:35px; \"><span class=\"separator\" style=\" width:60px;  background:#ffdd00;  left:50%;height:100%; margin-left: -30px;position: absolute;\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid vc_custom_1775573548113 vc_row-has-fill\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p class=\"font-claude-response-body break-words whitespace-normal leading-&#091;1.7&#093;\">All measurement, analysis, and reporting functions are available remotely:<\/p>\n<ul class=\"&#091;li_&amp;&#093;:mb-0 &#091;li_&amp;&#093;:mt-1 &#091;li_&amp;&#093;:gap-1 &#091;&amp;:not(:last-child)_ul&#093;:pb-1 &#091;&amp;:not(:last-child)_ol&#093;:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\">\n<li class=\"whitespace-normal break-words pl-2\">Synchrophasor &amp; RoCoF measurement (PMU, IEC\/IEEE 60255-118-1)<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Power quality monitoring, harmonics, interharmonics, supraharmonics up to 500 kHz<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Transient recording and disturbance analysis<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Continuous raw data recording at full sampling rate<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Wide Area Monitoring (WAMS) via SmartGRID EDGE PDC<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Report generation: EN50160, IEEE519, IEC61000-2-4 and others<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Export: CSV, XLS, PDF, Comtrade, PQDiff<\/li>\n<\/ul>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"wpb_content_element services_media style_1\"><h5><a href=\"#\"><\/a><\/h5><p><\/p>\n<div style=\"width: 940px;\" class=\"wp-video\"><video class=\"wp-video-shortcode\" id=\"video-10521-1\" width=\"940\" height=\"529\" preload=\"metadata\" controls=\"controls\"><source type=\"video\/mp4\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2025\/07\/Supraharmonische.mp4?_=1\" \/><a href=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2025\/07\/Supraharmonische.mp4\">https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2025\/07\/Supraharmonische.mp4<\/a><\/video><\/div>\n<p><\/p><\/div><\/div><\/div><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a19ca9bc3622\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"background-color: #F6F6F6; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 36px;color: #1c1c1c;text-align: center\" >Technical Excellence That Delivers Results<\/h2><\/div><div class=\"codeless_separator\" style=\" height:1px;  margin-top:0px;  margin-bottom:35px; \"><span class=\"separator\" style=\" width:60px;  background:#ffdd00;  left:50%;height:100%; margin-left: -30px;position: absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>The PQA 8000H-RM shares its voltage level coverage, current sensor compatibility, supraharmonic measurement, safety specifications, complying standards, and software functions with the portable NEO PQA 8000H.<\/p>\n<p>\u2192 <a href=\"https:\/\/www.neo-messtechnik.com\/pqa8000\"><strong>[See full measurement specifications on the PQA 8000H page]<\/strong><\/a><\/p>\n\n\t\t<\/div> \n\t<\/div> <div class=\"vc_row wpb_row vc_inner vc_row-fluid vc_row-o-content-middle vc_row-flex\"><div class=\"wpb_column vc_column_container vc_col-sm-4\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"text-align: center\" >Access the flyer:<\/h2><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-4\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"wpb_content_element button \"><a  target=\"_blank\"  class=\"btn-bt align-left default\" href=\"https:\/\/neo-messtechnik.com\/wp-content\/uploads\/simple-file-list\/Documentations-User-Manuals-Catalogues\/NEO_PQA8000H_Flyer_EN.pdf\"><span>Download in English<\/span><i class=\"\"><\/i><\/a><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-4\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><\/div><\/div><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a19ca9bc4d69\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     wpb_animate_when_almost_visible wpb_fadeInUp fadeInUp \" style=\"background-color: #FFFFFF; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_row wpb_row vc_inner vc_row-fluid vc_custom_1775577937315 vc_row-has-fill vc_row-o-content-middle vc_row-flex\"><div class=\"wpb_column vc_column_container vc_col-sm-10\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 36px;color: #1c1c1c;text-align: left\" >Built In Phasor Measurement Unit<\/h2><\/div><div class=\"codeless_separator\" style=\" height:1px;  margin-top:0px;  margin-bottom:35px; \"><span class=\"separator\" style=\" width:60px;  background:#ffdd00;  left:50%;height:100%; margin-left: -30px;position: absolute;\"><\/span><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p class=\"font-claude-response-body break-words whitespace-normal leading-&#091;1.7&#093;\">The PQA 8000H-RM includes full PMU functionality compliant with IEC\/IEEE 60255-118-1. It measures synchrophasors, frequency, and Rate of Change of Frequency (RoCoF) \u2014 all referenced to UTC via GPS.<\/p>\n<ul class=\"&#091;li_&amp;&#093;:mb-0 &#091;li_&amp;&#093;:mt-1 &#091;li_&amp;&#093;:gap-1 &#091;&amp;:not(:last-child)_ul&#093;:pb-1 &#091;&amp;:not(:last-child)_ol&#093;:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3\">\n<li class=\"whitespace-normal break-words pl-2\">TVE (Total Vector Error): \u2264 0.01% \u2014 100\u00d7 more accurate than the 1% standard requirement<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Angle accuracy: \u2264 0.003\u00b0<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Reporting rates: up to 200 fps (Class M and P simultaneously)<\/li>\n<li class=\"whitespace-normal break-words pl-2\">TCP and UDP streaming to PDC<\/li>\n<li class=\"whitespace-normal break-words pl-2\">Compatible with SmartGRID EDGE WAMS software<\/li>\n<\/ul>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-2\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"wpb_content_element button \"><a  class=\"btn-bt align-center default\" href=\"mailto:sales@neo-messtechnik.com\"><span>Read AppNote<\/span><i class=\"\"><\/i><\/a><\/div><\/div><\/div><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><div id=\"fws_6a19ca9bc5f68\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el standard_section     \" style=\"\" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 36px;color: #1c1c1c;text-align: center\" >More key facts and figures<\/h2><\/div><div class=\"codeless_separator\" style=\" height:1px;  margin-top:0px;  margin-bottom:35px; \"><span class=\"separator\" style=\" width:60px;  background:#ffdd00;  left:50%;height:100%; margin-left: -30px;position: absolute;\"><\/span><\/div><div class=\"vc_tta-container\" data-vc-action=\"collapseAll\"><div class=\"vc_general vc_tta vc_tta-accordion vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-o-shape-group vc_tta-controls-align-default vc_tta-o-all-clickable\"><div class=\"vc_tta-panels-container\"><div class=\"vc_tta-panels\"><div class=\"vc_tta-panel\" id=\"1775569589998-60437795-412e\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1775569589998-60437795-412e\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Power Quality<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\"><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><em>according to IEC 61000-4-30 Ed.3 and IEC 62586<\/em><\/p>\n<p><strong>Harmonics, Interharmonics and THD<\/strong>:<br \/>\nClass A<br \/>\n<strong>Higher Frequencies and Supraharmonics:<\/strong><br \/>\n2 &#8211; 9 kHz (200 Hz band)<br \/>\n2 &#8211; 500 kHz (2 kHz band)<br \/>\n<strong>Symmetrical Components &amp; Unbalance<\/strong>:<br \/>\nClass A ((Pos-, Neg- and Zero Sequence))<br \/>\n<strong>Flicker (PST, PLT, Pinst) and RVC:<\/strong><br \/>\nClass A<\/p>\n\n\t\t<\/div> \n\t<\/div> \n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p>.<\/p>\n<p><strong>Voltage Events<\/strong>:<br \/>\nClass A (dip, swell, interruption \u2013 time, extrema, length)<br \/>\n<strong>Frequency:<\/strong><br \/>\n10 sec, AVE, MIN, MAX<br \/>\n<strong>Voltage, Current:<br \/>\n<\/strong>RMS, AVE, MIN, MAX, \u00bd Period-values, 200ms, 10s, 10min<br \/>\n<strong>Time Synchronisation:<\/strong><br \/>\nClass A<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_tta-panel\" id=\"1775569592020-d5e3f465-6a8a\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1775569592020-d5e3f465-6a8a\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Power<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\"><div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/power_4.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_left\" \/><\/div><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>Power Calculation:<br \/>\n<\/strong>P, Q, S, PF, cos phi, D, DH, QH<\/p>\n<p><strong>Frequency:<br \/>\n<\/strong>10 sec, AVE, MIN, MAX<\/p>\n<p><strong>Voltage, Current:<br \/>\n<\/strong>RMS, AVE, MIN, MAX, \u00bd Period-values, 200ms, 10s, 10min<\/p>\n<p><strong>Power Calculation:<br \/>\n<\/strong>P, Q, S, PF, cos phi, D, DH, QH<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>Energy:<br \/>\n<\/strong>Total, positive, negative (P, Q, P+, P-, Q+, Q-)<\/p>\n<p><strong>Efficiency:<br \/>\n<\/strong>DC \/ AC, U-I Curve for PV<\/p>\n<p><strong>Wiring:<\/strong><br \/>\nDC, 1-Phase, 2-Phase, 3-Phase Star and Delta<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_tta-panel\" id=\"1775569594113-bee31d99-3a05\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1775569594113-bee31d99-3a05\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Waveform &amp; Transients<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\"><div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/waveform.png\" alt=\"Alt Text\" class=\"type_image animated fadeInnone alignment_left\" \/><\/div><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>MIN, MAX, RMS, AVE:<br \/>\n<\/strong>U, I, P, Q, S, f, PF, phi, THD, Harmonics, Interharm., Unbalance, etc.<br \/>\n<strong>ENVELOPE \/ WINDOW:<br \/>\n<\/strong>U, I<br \/>\n<strong>DELTA:<br \/>\n<\/strong>dU, dI, df, dP, etc.<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>DERIVATE (RATE OF CHANGE):<br \/>\n<\/strong>dU\/dt, df\/dt etc. \u2026 per ms, number of periods or half-period<br \/>\n<strong>VOLTAGE SIGNALLING:<br \/>\n<\/strong>Threshold<br \/>\n<strong>EN50160:<br \/>\n<\/strong>Trigger on any EN50160 parameter (Max, Quantil)<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_tta-panel\" id=\"1775569596252-bc213c3b-edb9\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1775569596252-bc213c3b-edb9\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Disturbances and System Dynamics<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\"><div class=\"wpb_content_element media_align_left media media_el animate_onoffset \"><div class=\"media_wrapper\" ><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/04\/disturbance_pqm.png\" alt=\"Alt Text\" class=\"type_image animated fadeInLeft alignment_left\" \/><\/div><\/div>\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>1\/2 PERIOD TRIGGER:<\/strong><br \/>\nU, I, P, Q, S, f, PF, phi, THD, Harmonics, Interharm., Unbalance, etc.<\/p>\n<p><strong>SYMMETRICAL COMPONENTS:<\/strong><br \/>\nPositive-, Negative-, Zerosequence<\/p>\n<p><strong>Phasor Measurement Unit (PMU)<\/strong><br \/>\naccording to IEEE C37.118: Total Vector Error 0.01% (typ.), Angle Error 0.003\u00b0(typ)<\/p>\n<p><strong>RATE OF CHANGE OF FREQUENCY (ROCOF)<\/strong><\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><div class=\"vc_tta-panel\" id=\"1775569597149-512412e7-5cc7\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1775569597149-512412e7-5cc7\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Complying Standards<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>POWER QUALITY, HARMONICS, FLICKER:<\/strong><br \/>\nIEC61000-4-30 Ed. 3 Class A \/ IEC61000-4-7 \/ IEC61000-4-15 \/\u00a0 IEC62586-2 Ed. 2 \/ IEC62586-1<br \/>\n<strong>PUBLIC GRID, RAILWAY AND INDUSTRY<\/strong><br \/>\nEN50160 \/ EN50163 \/ IEC61000-2-2 \/ IEC61000-2-4 (Class 1; 2; 3) \/ IEEE519\u00a0 \/ IEEE 1159 \/ IEC61000-2-12 \/ NRS048<br \/>\n<strong>WIND POWER, RENEWABLES AND GRID CODES<\/strong><br \/>\nIEC61400-21 \/ IEC61400-12 \/ FGW-TR3 \/ VDE N-4105 \/ VDE N-4100 \/ VDE N-4110 \/ D-A-CH-CZ \/ BDEW \/ ROCOF \/ IEEE C37.118-2005 (PMU)<br \/>\n<strong>MOTORS, TRANSFORMERS AND ELECTRICAL EQUIPMENT<\/strong><br \/>\nIEC60034 \/ IEC 60076-1 \/ IEC61000-3-2 \/ IEC61000-3-3 \/ IEC61000-3-11 \/ IEC61000-3-12<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><div class=\"vc_tta-panel\" id=\"1775572708049-2d5e67f9-085d\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1775572708049-2d5e67f9-085d\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Instrument Options<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p><strong>PQA8000 RM:<\/strong> Standard instrument configuration with 4 current inputs<\/p>\n<p><strong>PQA8000-P RM:<\/strong> Instrument with 6x current inputs and 2x Analogue Inputs<\/p>\n<p><strong>PQA8000-M RM:<\/strong> Instrument with 8x current inputs<\/p>\n<p><strong>OPTION-DC 110V:<\/strong> Option DC power supply from 48V to 110V DC (instead of 24 \u2013 48V DC)<\/p>\n<p>Screw terminals are also available as an option for the voltage inputs and for the power supply<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><div class=\"vc_tta-panel\" id=\"1775574489618-7915bf39-8322\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h4 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#1775574489618-7915bf39-8322\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Applications<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h4><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \">\n\t\t<div class=\"wpb_wrapper\" >\n\t\t\t<p class=\"font-claude-response-body break-words whitespace-normal leading-&#091;1.7&#093;\">The PQA 8000H-RM is deployed wherever continuous, high-precision power quality monitoring is required over extended periods \u2014 without the need for on-site operation.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-&#091;1.7&#093;\"><strong>Substations &amp; Grid Connection Points<\/strong> Permanent monitoring of voltage quality, harmonics, and grid events at transmission and distribution level.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-&#091;1.7&#093;\"><strong>Battery Energy Storage Systems (BESS)<\/strong> High-accuracy measurement for FCAS compliance, asset verification, and grid support documentation.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-&#091;1.7&#093;\"><strong>Renewable Energy Integration<\/strong> Monitoring of PV, wind, and hybrid installations \u2014 including DC measurements and grid code compliance assessment.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-&#091;1.7&#093;\"><strong>Wide Area Monitoring (WAMS)<\/strong> Multi-site synchrophasor data via PDC integration \u2014 real-time grid observability across large geographic areas.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-&#091;1.7&#093;\"><strong>Industrial &amp; Railway<\/strong> Power quality assessment in industrial grids, railway supply systems, and high-distortion environments.<\/p>\n<p class=\"font-claude-response-body break-words whitespace-normal leading-&#091;1.7&#093;\"><strong>Research &amp; Grid Model Validation<\/strong> High-resolution waveform data for grid simulation validation, model calibration, and post-event analysis.<\/p>\n\n\t\t<\/div> \n\t<\/div> <\/div><\/div><\/div><\/div><\/div><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><section class=\"vc_section\"><div id=\"fws_6a19ca9bce80d\" class=\"vc_row wpb_row vc_row-fluid  animate_onoffset row-dynamic-el section-style     \" style=\"background-color: #f9f9f9; padding-bottom: 0px ; \" ><div  style=\"position: absolute;top: 0;\"><\/div><div class=\"container  dark\"><div class=\"section_clear\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container \" style=\"\" data-animation=\"none\" data-delay=\"\">\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 36px;color: #1c1c1c;text-align: center\" >NEO Applications<\/h2><\/div><div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"font-size: 16px;color: #1c1c1c;line-height: 24px;text-align: center\" >reveal what conventional measurement cannot detect<\/h2><\/div><div class=\"codeless_separator\" style=\" height:1px;  margin-top:0px;  margin-bottom:35px; \"><span class=\"separator\" style=\" width:60px;  background:#ffdd00;  left:50%;height:100%; margin-left: -30px;position: absolute;\"><\/span><\/div><div class=\"vc_row wpb_row vc_inner vc_row-fluid vc_column-gap-10 vc_row-o-equal-height vc_row-o-content-top vc_row-flex\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"text-align: center\" ><a href=\"https:\/\/www.neo-messtechnik.com\/applications-power-quality\" title=\"Applications \u2013 PQ\">Power Quality<\/a><\/h2><\/div><div class=\"wpb_content_element media_align_center media media_el animate_onoffset \"><div class=\"media_wrapper\" style=\"width:600px;position:relative; left:50%; margin-left:-300px;\" ><a href=\"https:\/\/www.neo-messtechnik.com\/applications-power-quality\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/03\/power-landscape.jpg\" alt=\"Media\" class=\"type_image animated fadeInnone alignment_center\" \/><\/a><\/div><\/div><div class=\"wpb_content_element button \"><a  target=\"_blank\"  class=\"btn-bt align-center default\" href=\"http:\/\/www.neo-messtechnik.com\/applications-power-quality\"><span>See More<\/span><\/a><\/div><\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_custom_heading wpb_content_element\" ><h2 style=\"text-align: center\" ><a href=\"https:\/\/www.neo-messtechnik.com\/applications-photovoltaic\" title=\"Applications \u2013 PQ\">Photovoltaic<\/a><\/h2><\/div><div class=\"wpb_content_element media_align_center media media_el animate_onoffset \"><div class=\"media_wrapper\" style=\"width:600px;position:relative; left:50%; margin-left:-300px;\" ><a href=\"https:\/\/www.neo-messtechnik.com\/applications-photovoltaic\" target=\"_blank\"><img decoding=\"async\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2025\/09\/PV-Neo-Messtechnik.png\" alt=\"Media\" class=\"type_image animated fadeInnone alignment_center\" \/><\/a><\/div><\/div><div class=\"wpb_content_element button \"><a  target=\"_blank\"  class=\"btn-bt align-center default\" href=\"https:\/\/www.neo-messtechnik.com\/applications-photovoltaic\"><span>See More<\/span><\/a><\/div><\/div><\/div><\/div><\/div><div class=\"vc_empty_space\"   style=\"height: 69px\"><span class=\"vc_empty_space_inner\"><\/span><\/div>\n\t\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div><\/section>\n<\/div>","protected":false},"excerpt":{"rendered":"The Premium Device for Professional Monitoring With the new PQA 8000H-RM, NEO Messtechnik brings the full measurement capability of the PQA 8000H into a 19\" rackmount form factor \u2014 designed for permanent installation in substations, battery energy storage systems, and grid-connected infrastructure. The instrument retains all hardware and software capabilities of its portable variant, while [...]","protected":false},"author":21,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-10521","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PQA 8000H Rack Mount Power Quality Analyzer - NEO Messtechnik<\/title>\n<meta name=\"description\" content=\"PQA 8000H-RM: Class A++ power quality analyzer in a 19\u2033 rack mount. 1 MS\/s, PMU, 500 kHz supraharmonics \u2014 built for permanent installation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.neo-messtechnik.com\/de\/pqa-8000h-rack-mount-power-quality-analyzer\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PQA 8000H Rack Mount Power Quality Analyzer - NEO Messtechnik\" \/>\n<meta property=\"og:description\" content=\"PQA 8000H-RM: Class A++ power quality analyzer in a 19\u2033 rack mount. 1 MS\/s, PMU, 500 kHz supraharmonics \u2014 built for permanent installation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.neo-messtechnik.com\/de\/pqa-8000h-rack-mount-power-quality-analyzer\/\" \/>\n<meta property=\"og:site_name\" content=\"NEO Messtechnik\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-27T08:01:24+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"6\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/pqa-8000h-rack-mount-power-quality-analyzer\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/pqa-8000h-rack-mount-power-quality-analyzer\",\"name\":\"PQA 8000H Rack Mount Power Quality Analyzer - NEO Messtechnik\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\"},\"datePublished\":\"2026-04-07T16:07:24+00:00\",\"dateModified\":\"2026-04-27T08:01:24+00:00\",\"description\":\"PQA 8000H-RM: Class A++ power quality analyzer in a 19\u2033 rack mount. 1 MS\\\/s, PMU, 500 kHz supraharmonics \u2014 built for permanent installation.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/pqa-8000h-rack-mount-power-quality-analyzer#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.neo-messtechnik.com\\\/pqa-8000h-rack-mount-power-quality-analyzer\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/pqa-8000h-rack-mount-power-quality-analyzer#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PQA 8000H Rack Mount Power Quality Analyzer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"name\":\"NEO Messtechnik\",\"description\":\"Power Quality with perfection\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\",\"name\":\"NEO Messtechnik GmbH\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"contentUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"width\":466,\"height\":264,\"caption\":\"NEO Messtechnik GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/linkedin.com\\\/company\\\/neo-messtechnik\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PQA 8000H Rack Mount Power Quality Analyzer - NEO Messtechnik","description":"PQA 8000H-RM: Class A++ power quality analyzer in a 19\u2033 rack mount. 1 MS\/s, PMU, 500 kHz supraharmonics \u2014 built for permanent installation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.neo-messtechnik.com\/de\/pqa-8000h-rack-mount-power-quality-analyzer\/","og_locale":"de_DE","og_type":"article","og_title":"PQA 8000H Rack Mount Power Quality Analyzer - NEO Messtechnik","og_description":"PQA 8000H-RM: Class A++ power quality analyzer in a 19\u2033 rack mount. 1 MS\/s, PMU, 500 kHz supraharmonics \u2014 built for permanent installation.","og_url":"https:\/\/www.neo-messtechnik.com\/de\/pqa-8000h-rack-mount-power-quality-analyzer\/","og_site_name":"NEO Messtechnik","article_modified_time":"2026-04-27T08:01:24+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"6\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.neo-messtechnik.com\/pqa-8000h-rack-mount-power-quality-analyzer","url":"https:\/\/www.neo-messtechnik.com\/pqa-8000h-rack-mount-power-quality-analyzer","name":"PQA 8000H Rack Mount Power Quality Analyzer - NEO Messtechnik","isPartOf":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#website"},"datePublished":"2026-04-07T16:07:24+00:00","dateModified":"2026-04-27T08:01:24+00:00","description":"PQA 8000H-RM: Class A++ power quality analyzer in a 19\u2033 rack mount. 1 MS\/s, PMU, 500 kHz supraharmonics \u2014 built for permanent installation.","breadcrumb":{"@id":"https:\/\/www.neo-messtechnik.com\/pqa-8000h-rack-mount-power-quality-analyzer#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.neo-messtechnik.com\/pqa-8000h-rack-mount-power-quality-analyzer"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.neo-messtechnik.com\/pqa-8000h-rack-mount-power-quality-analyzer#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.neo-messtechnik.com\/"},{"@type":"ListItem","position":2,"name":"PQA 8000H Rack Mount Power Quality Analyzer"}]},{"@type":"WebSite","@id":"https:\/\/www.neo-messtechnik.com\/en\/#website","url":"https:\/\/www.neo-messtechnik.com\/en\/","name":"NEO Messtechnik","description":"Power Quality with perfection","publisher":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.neo-messtechnik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization","name":"NEO Messtechnik GmbH","url":"https:\/\/www.neo-messtechnik.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","contentUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","width":466,"height":264,"caption":"NEO Messtechnik GmbH"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/linkedin.com\/company\/neo-messtechnik"]}]}},"_links":{"self":[{"href":"https:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/pages\/10521","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/users\/21"}],"replies":[{"embeddable":true,"href":"https:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/comments?post=10521"}],"version-history":[{"count":37,"href":"https:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/pages\/10521\/revisions"}],"predecessor-version":[{"id":10595,"href":"https:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/pages\/10521\/revisions\/10595"}],"wp:attachment":[{"href":"https:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/media?parent=10521"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}