{"id":8450,"date":"2023-10-17T15:30:01","date_gmt":"2023-10-17T13:30:01","guid":{"rendered":"https:\/\/www.neo-messtechnik.com\/?p=8450"},"modified":"2025-10-07T10:39:15","modified_gmt":"2025-10-07T08:39:15","slug":"solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules","status":"publish","type":"post","link":"http:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules","title":{"rendered":"Messung der solaren Einstrahlung f\u00fcr Photovoltaikanlagen: Pyranometer, Referenzzellen und Referenzmodule"},"content":{"rendered":"<p>Die genaue Messung der Solarstrahlung ist von entscheidender Bedeutung f\u00fcr die optimale Leistung und Effizienz von Photovoltaikanlagen (PV). Sie erm\u00f6glicht es Ingenieuren und Betreibern, diese Systeme effektiv zu planen, zu \u00fcberwachen und zu warten. In diesem Artikel werden wir die Gr\u00fcnde f\u00fcr die Notwendigkeit einer zuverl\u00e4ssigen Messung der Solarstrahlung und drei wichtige Instrumente f\u00fcr die Messung der Solarstrahlung in PV-Anlagen untersuchen: Pyranometer, Referenzzellen und Referenzmodule.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_83 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Inhaltsverzeichnis<\/p>\n<label for=\"ez-toc-cssicon-toggle-item-69fe8675401d0\" class=\"ez-toc-cssicon-toggle-label\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #000000;color:#000000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #000000;color:#000000\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/label><input type=\"checkbox\"  id=\"ez-toc-cssicon-toggle-item-69fe8675401d0\" checked aria-label=\"Toggle\" \/><nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"http:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\/#Why_is_it_important_to_have_a_reliable_solar_irradiance_measurement_method\" >Warum ist eine zuverl\u00e4ssige Methode zur Messung der Solarstrahlung so wichtig?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"http:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\/#Pyranometers\" >Pyranometer<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"http:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\/#Reference_Cells\" >Referenzzellen<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"http:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\/#Reference_Modules\" >Referenzmodule<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"http:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\/#Solar_Irradiance_Measurement_for_IV-curve_Tracing\" >Messung der solaren Bestrahlungsst\u00e4rke zur IV-Kennlinienmessung<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"http:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\/#Wrapping_up\" >Zum Abschluss<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\" id=\"block-e55ad5e2-9ca6-4fd9-aa53-f8850cd9d8b4\"><span class=\"ez-toc-section\" id=\"Why_is_it_important_to_have_a_reliable_solar_irradiance_measurement_method\"><\/span>Warum ist eine zuverl\u00e4ssige Methode zur Messung der Solarstrahlung so wichtig?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Es gibt mehrere Gr\u00fcnde f\u00fcr eine pr\u00e4zise Messung der Solarstrahlung. Ein Beispiel w\u00e4re die Bestimmung der Gr\u00f6\u00dfe eines Solarenergiesystems (z. B. PV-Module, solarthermische Kollektoren). Hierf\u00fcr sind genaue Daten zur Sonneneinstrahlung erforderlich, um sicherzustellen, dass das System angemessen dimensioniert ist, um die gew\u00fcnschten Energieerzeugungsziele zu erreichen. <\/p>\n\n\n\n<p>Ein weiteres wichtiges Beispiel w\u00e4re die Wartung einer PV-Anlage. Die Messung von IV-Kennlinien erfordert Echtzeit-Einstrahlungsdaten, um die erwarteten Werte zu berechnen und somit Fehler in der Anlage aufzuzeigen. Die Einstrahlungsdaten helfen auch dabei, die Energiemenge abzusch\u00e4tzen, die ein Solarsystem in einem bestimmten Zeitraum voraussichtlich produzieren wird. Diese Informationen sind f\u00fcr die Finanzmodellierung, die Berechnung der Kapitalrendite (ROI) und die Bewertung der Durchf\u00fchrbarkeit von Projekten von entscheidender Bedeutung. <\/p>\n\n\n\n<p>Bei netzgekoppelten Systemen hilft die Kenntnis der Solarstrahlung bei der stabilen Integration von Solarstrom in das Stromnetz. Netzbetreiber k\u00f6nnen Schwankungen in der Solarstromerzeugung besser vorhersehen und steuern.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Pyranometers\"><\/span>Pyranometer<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"740\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/SR20_pyranometer_2.jpg\" alt=\"\" class=\"wp-image-8451\" style=\"width:461px;height:332px\" srcset=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/SR20_pyranometer_2.jpg 1024w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/SR20_pyranometer_2-300x217.jpg 300w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/SR20_pyranometer_2-830x600.jpg 830w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/SR20_pyranometer_2-768x555.jpg 768w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/SR20_pyranometer_2-18x12.jpg 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p>Pyranometer sind Instrumente, die speziell f\u00fcr die Messung der gesamten Solarstrahlung (globale horizontale Bestrahlungsst\u00e4rke), die auf eine Oberfl\u00e4che f\u00e4llt, entwickelt wurden. Sie sind wichtige Instrumente f\u00fcr die Bewertung und Leistungs\u00fcberwachung von PV-Anlagen.<\/p>\n\n\n\n<p><strong>Vorteile:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Genauigkeit:<\/strong> Pyranometer bieten eine hohe Genauigkeit bei der Messung der Gesamtsonnenbestrahlungsst\u00e4rke \u00fcber einen breiten Spektralbereich.<\/li>\n\n\n\n<li><strong>Geringe Wartung<\/strong> Es handelt sich im Allgemeinen um wartungsarme Instrumente, die \u00fcber l\u00e4ngere Zeitr\u00e4ume zuverl\u00e4ssige Daten liefern k\u00f6nnen.<\/li>\n\n\n\n<li><strong>Kosteng\u00fcnstig<\/strong> Im Vergleich zu anderen Messger\u00e4ten sind Pyranometer kosteng\u00fcnstig und in der Solarenergiebranche weit verbreitet.<\/li>\n<\/ul>\n\n\n\n<p><strong>Nachteile:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Direktionale Empfindlichkeit:<\/strong> Pyranometer reagieren empfindlich auf den Einfallswinkel des Sonnenlichts, was unter Umst\u00e4nden zu einer Untersch\u00e4tzung der Bestrahlungsst\u00e4rke unter nicht normalen Einfallsbedingungen f\u00fchrt.<\/li>\n\n\n\n<li><strong>Spektrale Abh\u00e4ngigkeit:<\/strong> Einige Pyranometer haben eine Spektralempfindlichkeit, die nicht perfekt mit dem Sonnenspektrum \u00fcbereinstimmt, was zu kleinen Messfehlern f\u00fchren kann.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Reference_Cells\"><\/span>Referenzzellen<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Referenzzellen dienen als Standard f\u00fcr die Kalibrierung anderer photovoltaischer Ger\u00e4te. Sie bieten eine auf internationale Standards r\u00fcckf\u00fchrbare Messung und spielen eine entscheidende Rolle bei der Gew\u00e4hrleistung der Genauigkeit der Leistungsdaten von PV-Systemen.<\/p>\n\n\n\n<p><strong>Vorteile:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Nachvollziehbarkeit:<\/strong> Referenzzellen bieten r\u00fcckf\u00fchrbare Messungen auf internationale Standards und schaffen eine klare Kalibrierungshierarchie.<\/li>\n\n\n\n<li><strong>Hohe Genauigkeit:<\/strong> Diese Zellen sind sorgf\u00e4ltig kalibriert und liefern extrem genaue Messungen der Solarstrahlung.<\/li>\n\n\n\n<li><strong>Stabilit\u00e4t<\/strong> Gut gewartete Referenzzellen k\u00f6nnen ihre Genauigkeit \u00fcber lange Zeitr\u00e4ume beibehalten.<\/li>\n<\/ul>\n\n\n\n<p><strong>Nachteile:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Alterung:<\/strong> Auch die Referenzzelle kann altern. Der Alterungseffekt hat einen Einfluss auf die Messergebnisse und kann diese verf\u00e4lschen.<\/li>\n\n\n\n<li><strong>Temperaturabh\u00e4ngigkeit:<\/strong> Referenzzellen k\u00f6nnen bei Temperaturschwankungen schlechte Ergebnisse liefern, da sie stark temperaturabh\u00e4ngig sind.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Reference_Modules\"><\/span>Referenzmodule<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Referenzmodule sind im Wesentlichen PV-Module, die so charakterisiert sind, dass sie genaue Messungen der Sonneneinstrahlung liefern. Sie ahmen das Verhalten von Standard-PV-Modulen unter bekannten Bedingungen nach und werden f\u00fcr Kalibrierungs- und Validierungszwecke verwendet.<\/p>\n\n\n\n<p><strong>Vorteile:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Realit\u00e4tsnahe Simulation:<\/strong> Referenzmodule bieten im Vergleich zu isolierten Referenzzellen eine realistischere Darstellung der PV-Systemleistung.<\/li>\n\n\n\n<li><strong>Anwendungsspezifisch:<\/strong> Sie k\u00f6nnen auf die Eigenschaften der in einem Projekt verwendeten PV-Module zugeschnitten werden.<\/li>\n\n\n\n<li><strong>Verifizierung der Kalibrierung:<\/strong> Die Verwendung von Referenzmodulen erm\u00f6glicht eine regelm\u00e4\u00dfige \u00dcberpr\u00fcfung der Genauigkeit der Messungen der PV-Anlage.<\/li>\n<\/ul>\n\n\n\n<p><strong>Nachteile:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Komplexit\u00e4t:<\/strong> Die Einrichtung und Wartung eines Referenzmoduls kann komplexer sein als die einer Referenzzelle und erfordert unter Umst\u00e4nden eine sorgf\u00e4ltigere Beachtung der Umweltbedingungen.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Solar_Irradiance_Measurement_for_IV-curve_Tracing\"><\/span>Messung der solaren Bestrahlungsst\u00e4rke zur IV-Kennlinienmessung<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Wir bei NEO Messtechnik verwenden das \"LPSILICON-PYRA 04\" f\u00fcr die IV-Kennlinienmessung. Wie auf dem Bild unten zu sehen ist, deckt dieses Pyranometer den gr\u00f6\u00dften Teil des nutzbaren Anteils der Sonnenstrahlung ab. Als Energieverluste werden Transmissionsverluste und Thermalisierungsverluste ber\u00fccksichtigt. Bei den Transmissionsverlusten ist die Energie des einfallenden Photons zu gering, um die Bandl\u00fccke des Siliziummoduls zu \u00fcberwinden. Bei den Thermalisierungsverlusten hingegen ist die Energie des Photons zu hoch, so dass ein Teil davon als W\u00e4rme verloren geht.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"382\" src=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/Spektrum-Pyranometer-de.png\" alt=\"\" class=\"wp-image-8458\" srcset=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/Spektrum-Pyranometer-de.png 700w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/Spektrum-Pyranometer-de-300x164.png 300w, https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/Spektrum-Pyranometer-de-18x10.png 18w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><figcaption class=\"wp-element-caption\">abge\u00e4ndert nach (Photovoltaik &#8211; Lehrbuch zu Grundlagen, Technologie und Praxis, Mertens 2022)<\/figcaption><\/figure>\n\n\n\n<p>Zusammenfassend l\u00e4sst sich sagen, dass jedes Instrument - Pyranometer, Referenzzellen und Referenzmodule - eine wichtige Rolle bei der genauen Messung der Sonneneinstrahlung f\u00fcr PV-Systeme spielt. Pyranometer bieten kosteng\u00fcnstige und praktische Messungen der Gesamtbestrahlungsst\u00e4rke. Referenzzellen liefern r\u00fcckf\u00fchrbare und hochgenaue Kalibrierungsstandards. Referenzmodule sind zwar komplizierter einzurichten, bieten aber eine realistischere Darstellung der PV-Systemleistung. Wenn man die St\u00e4rken und Grenzen dieser Instrumente kennt, kann man die am besten geeignete Methode f\u00fcr eine bestimmte Anwendung ausw\u00e4hlen und so den Erfolg und die Effizienz von PV-Anlagen sicherstellen.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Wrapping_up\"><\/span>Zum Abschluss<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p>Wo finde ich weitere Informationen?<\/p>\n\n\n\n<div class=\"wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items8450_8be40c-ff kt-svg-icon-list-columns-1 alignnone kt-list-icon-aligntop\"><ul class=\"kt-svg-icon-list\">\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-8450_c45ead-d8 kt-svg-icon-list-style-default\"><span data-name=\"fe_checkCircle\" data-stroke=\"2\" data-class=\"kt-svg-icon-list-single\" class=\"kadence-dynamic-icon\"><\/span><span class=\"kt-svg-icon-list-text\">Klicken Sie einfach auf den Link und <strong><a href=\"http:\/\/www.neo-messtechnik.com\/de\/pv-master\/\">besuchen Sie unsere Produktseite<\/a><\/strong><\/span><\/li>\n\n\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-8450_7ca15f-2c kt-svg-icon-list-style-default\"><span data-name=\"fe_checkCircle\" data-stroke=\"2\" data-class=\"kt-svg-icon-list-single\" class=\"kadence-dynamic-icon\"><\/span><span class=\"kt-svg-icon-list-text\">Fordern Sie online eine <strong>Produktvorstellung an<\/strong><\/span><\/li>\n\n\n\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-8450_987104-57 kt-svg-icon-list-style-default\"><span data-name=\"fe_checkCircle\" data-stroke=\"2\" data-class=\"kt-svg-icon-list-single\" class=\"kadence-dynamic-icon\"><\/span><span class=\"kt-svg-icon-list-text\">Wir sind per <a rel=\"noreferrer noopener\" href=\"https:\/\/www.neo-messtechnik.com\/de\/ueber-uns\/\" target=\"_blank\">Telefon<\/a> oder E-Mail f\u00fcr Sie erreichbar. Wir freuen uns auf Ihre Anfrage:<\/span><\/li>\n<\/ul><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:sales@neo-messtechnik.com\">\u00d6sterreich<\/a><\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:info@schotec.ch\">Schweiz<\/a><\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:neo@neomez.com\">S\u00fcdkorea<\/a><\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center\"><strong><a href=\"mailto:sales@dewe-tech.cn\">China<\/a><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"translation-block\">Ihre <a href=\"https:\/\/www.linkedin.com\/company\/neo-messtechnik\/\" target=\"_self\" rel=\"noreferrer noopener\">NEO Messtechnik Experten<\/a><\/p>\n\n\n\n<ul class=\"wp-block-social-links is-layout-flex wp-block-social-links-is-layout-flex\"><li class=\"wp-social-link wp-social-link-linkedin  wp-block-social-link\"><a href=\"https:\/\/linkedin.com\/company\/neo-messtechnik\" class=\"wp-block-social-link-anchor\"><svg width=\"24\" height=\"24\" viewbox=\"0 0 24 24\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\" focusable=\"false\"><path d=\"M19.7,3H4.3C3.582,3,3,3.582,3,4.3v15.4C3,20.418,3.582,21,4.3,21h15.4c0.718,0,1.3-0.582,1.3-1.3V4.3 C21,3.582,20.418,3,19.7,3z M8.339,18.338H5.667v-8.59h2.672V18.338z M7.004,8.574c-0.857,0-1.549-0.694-1.549-1.548 c0-0.855,0.691-1.548,1.549-1.548c0.854,0,1.547,0.694,1.547,1.548C8.551,7.881,7.858,8.574,7.004,8.574z M18.339,18.338h-2.669 v-4.177c0-0.996-0.017-2.278-1.387-2.278c-1.389,0-1.601,1.086-1.601,2.206v4.249h-2.667v-8.59h2.559v1.174h0.037 c0.356-0.675,1.227-1.387,2.526-1.387c2.703,0,3.203,1.779,3.203,4.092V18.338z\"><\/path><\/svg><span class=\"wp-block-social-link-label screen-reader-text\">LinkedIn<\/span><\/a><\/li>\n\n<li class=\"wp-social-link wp-social-link-youtube  wp-block-social-link\"><a href=\"https:\/\/www.youtube.com\/channel\/UC0SItHb-UNY0WNUhQtqhB7w\" class=\"wp-block-social-link-anchor\"><svg width=\"24\" height=\"24\" viewbox=\"0 0 24 24\" version=\"1.1\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" aria-hidden=\"true\" focusable=\"false\"><path d=\"M21.8,8.001c0,0-0.195-1.378-0.795-1.985c-0.76-0.797-1.613-0.801-2.004-0.847c-2.799-0.202-6.997-0.202-6.997-0.202 h-0.009c0,0-4.198,0-6.997,0.202C4.608,5.216,3.756,5.22,2.995,6.016C2.395,6.623,2.2,8.001,2.2,8.001S2,9.62,2,11.238v1.517 c0,1.618,0.2,3.237,0.2,3.237s0.195,1.378,0.795,1.985c0.761,0.797,1.76,0.771,2.205,0.855c1.6,0.153,6.8,0.201,6.8,0.201 s4.203-0.006,7.001-0.209c0.391-0.047,1.243-0.051,2.004-0.847c0.6-0.607,0.795-1.985,0.795-1.985s0.2-1.618,0.2-3.237v-1.517 C22,9.62,21.8,8.001,21.8,8.001z M9.935,14.594l-0.001-5.62l5.404,2.82L9.935,14.594z\"><\/path><\/svg><span class=\"wp-block-social-link-label screen-reader-text\">YouTube<\/span><\/a><\/li><\/ul>","protected":false},"excerpt":{"rendered":"<p>Accurate measurement of solar irradiance is paramount for the optimal performance and efficiency of photovoltaic (PV) systems. It enables engineers and operators to design, monitor, and maintain these systems effectively. In this discussion, we&#8217;ll explore the reasons for why we need a reliable solar irradiance measurement and three crucial instruments used in solar irradiance measurement [&hellip;]<\/p>\n","protected":false},"author":287,"featured_media":8458,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[50,93],"tags":[],"class_list":["post-8450","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news-and-trends","category-pv-inspection"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Solar Irradiance Measurement for Photovoltaic Systems: Pyranometers, Reference Cells, and Reference Modules - NEO Messtechnik<\/title>\n<meta name=\"description\" content=\"With this post series, we want to explain the different types of faults in photovoltaic modules in more detail. Let&#039;s start with shading.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Solar Irradiance Measurement for Photovoltaic Systems: Pyranometers, Reference Cells, and Reference Modules - NEO Messtechnik\" \/>\n<meta property=\"og:description\" content=\"With this post series, we want to explain the different types of faults in photovoltaic modules in more detail. Let&#039;s start with shading.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\/\" \/>\n<meta property=\"og:site_name\" content=\"NEO Messtechnik\" \/>\n<meta property=\"article:published_time\" content=\"2023-10-17T13:30:01+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-07T08:39:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/Spektrum-Pyranometer-en.png\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"382\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Andre\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Andre\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\"},\"author\":{\"name\":\"Andre\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/person\\\/be05894a9459650e0bfbbf0b78293e98\"},\"headline\":\"Solar Irradiance Measurement for Photovoltaic Systems: Pyranometers, Reference Cells, and Reference Modules\",\"datePublished\":\"2023-10-17T13:30:01+00:00\",\"dateModified\":\"2025-10-07T08:39:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\"},\"wordCount\":835,\"publisher\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/Spektrum-Pyranometer-en.png\",\"articleSection\":[\"News &amp; Trends\",\"PV Inspection\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\",\"name\":\"Solar Irradiance Measurement for Photovoltaic Systems: Pyranometers, Reference Cells, and Reference Modules - NEO Messtechnik\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/Spektrum-Pyranometer-en.png\",\"datePublished\":\"2023-10-17T13:30:01+00:00\",\"dateModified\":\"2025-10-07T08:39:15+00:00\",\"description\":\"With this post series, we want to explain the different types of faults in photovoltaic modules in more detail. Let's start with shading.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#primaryimage\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/Spektrum-Pyranometer-en.png\",\"contentUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2023\\\/10\\\/Spektrum-Pyranometer-en.png\",\"width\":700,\"height\":382},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"News &amp; Trends\",\"item\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/de\\\/kategorie\\\/news-and-trends\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Solar Irradiance Measurement for Photovoltaic Systems: Pyranometers, Reference Cells, and Reference Modules\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"name\":\"NEO Messtechnik\",\"description\":\"Power Quality with perfection\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#organization\",\"name\":\"NEO Messtechnik GmbH\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"contentUrl\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/Logo-german-english-3.png\",\"width\":466,\"height\":264,\"caption\":\"NEO Messtechnik GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/linkedin.com\\\/company\\\/neo-messtechnik\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.neo-messtechnik.com\\\/en\\\/#\\\/schema\\\/person\\\/be05894a9459650e0bfbbf0b78293e98\",\"name\":\"Andre\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/299c067a49b2eef997d0b47116bacf994fde701db121251538c7c2f1cfdcf4a4?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/299c067a49b2eef997d0b47116bacf994fde701db121251538c7c2f1cfdcf4a4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/299c067a49b2eef997d0b47116bacf994fde701db121251538c7c2f1cfdcf4a4?s=96&d=mm&r=g\",\"caption\":\"Andre\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Solar Irradiance Measurement for Photovoltaic Systems: Pyranometers, Reference Cells, and Reference Modules - NEO Messtechnik","description":"With this post series, we want to explain the different types of faults in photovoltaic modules in more detail. Let's start with shading.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\/","og_locale":"de_DE","og_type":"article","og_title":"Solar Irradiance Measurement for Photovoltaic Systems: Pyranometers, Reference Cells, and Reference Modules - NEO Messtechnik","og_description":"With this post series, we want to explain the different types of faults in photovoltaic modules in more detail. Let's start with shading.","og_url":"https:\/\/www.neo-messtechnik.com\/de\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules\/","og_site_name":"NEO Messtechnik","article_published_time":"2023-10-17T13:30:01+00:00","article_modified_time":"2025-10-07T08:39:15+00:00","og_image":[{"width":700,"height":382,"url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/Spektrum-Pyranometer-en.png","type":"image\/png"}],"author":"Andre","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"Andre","Gesch\u00e4tzte Lesezeit":"5\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#article","isPartOf":{"@id":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules"},"author":{"name":"Andre","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/person\/be05894a9459650e0bfbbf0b78293e98"},"headline":"Solar Irradiance Measurement for Photovoltaic Systems: Pyranometers, Reference Cells, and Reference Modules","datePublished":"2023-10-17T13:30:01+00:00","dateModified":"2025-10-07T08:39:15+00:00","mainEntityOfPage":{"@id":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules"},"wordCount":835,"publisher":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#primaryimage"},"thumbnailUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/Spektrum-Pyranometer-en.png","articleSection":["News &amp; Trends","PV Inspection"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules","url":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules","name":"Solar Irradiance Measurement for Photovoltaic Systems: Pyranometers, Reference Cells, and Reference Modules - NEO Messtechnik","isPartOf":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#primaryimage"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#primaryimage"},"thumbnailUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/Spektrum-Pyranometer-en.png","datePublished":"2023-10-17T13:30:01+00:00","dateModified":"2025-10-07T08:39:15+00:00","description":"With this post series, we want to explain the different types of faults in photovoltaic modules in more detail. Let's start with shading.","breadcrumb":{"@id":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#primaryimage","url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/Spektrum-Pyranometer-en.png","contentUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2023\/10\/Spektrum-Pyranometer-en.png","width":700,"height":382},{"@type":"BreadcrumbList","@id":"https:\/\/www.neo-messtechnik.com\/solar-irradiance-measurement-for-photovoltaic-systems-pyranometers-reference-cells-and-reference-modules#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.neo-messtechnik.com\/"},{"@type":"ListItem","position":2,"name":"News &amp; Trends","item":"https:\/\/www.neo-messtechnik.com\/de\/kategorie\/news-and-trends"},{"@type":"ListItem","position":3,"name":"Solar Irradiance Measurement for Photovoltaic Systems: Pyranometers, Reference Cells, and Reference Modules"}]},{"@type":"WebSite","@id":"https:\/\/www.neo-messtechnik.com\/en\/#website","url":"https:\/\/www.neo-messtechnik.com\/en\/","name":"NEO Messtechnik","description":"Power Quality with perfection","publisher":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.neo-messtechnik.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.neo-messtechnik.com\/en\/#organization","name":"NEO Messtechnik GmbH","url":"https:\/\/www.neo-messtechnik.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","contentUrl":"https:\/\/www.neo-messtechnik.com\/wp-content\/uploads\/2020\/02\/Logo-german-english-3.png","width":466,"height":264,"caption":"NEO Messtechnik GmbH"},"image":{"@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/linkedin.com\/company\/neo-messtechnik"]},{"@type":"Person","@id":"https:\/\/www.neo-messtechnik.com\/en\/#\/schema\/person\/be05894a9459650e0bfbbf0b78293e98","name":"Andre","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/299c067a49b2eef997d0b47116bacf994fde701db121251538c7c2f1cfdcf4a4?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/299c067a49b2eef997d0b47116bacf994fde701db121251538c7c2f1cfdcf4a4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/299c067a49b2eef997d0b47116bacf994fde701db121251538c7c2f1cfdcf4a4?s=96&d=mm&r=g","caption":"Andre"}}]}},"_links":{"self":[{"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/posts\/8450","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/users\/287"}],"replies":[{"embeddable":true,"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/comments?post=8450"}],"version-history":[{"count":6,"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/posts\/8450\/revisions"}],"predecessor-version":[{"id":8638,"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/posts\/8450\/revisions\/8638"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/media\/8458"}],"wp:attachment":[{"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/media?parent=8450"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/categories?post=8450"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.neo-messtechnik.com\/de\/wp-json\/wp\/v2\/tags?post=8450"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}